FAQ-how to solve the problem on array that host type of VIS is wrong and it cannot find disk after configuring rightly

Publication Date:  2012-10-10 Views:  130 Downloads:  0

Issue Description

Set wrong VIS type of host on array, VIS cannot find disk, but after modifying it to Linux, VIS can still not find disk.

Alarm Information

none

Handling Process

1. Make sure host type of VIS on array is linux.
2. Cut the cable of VIS array, scan disk on VIS and then VIS will delete the wrong information.
3. Insert the cable, scan disk on VIS, then you will find the right disk.

Root Cause

After scanning disk on VIS, it keep wrong disk information on VIS. Modifying type on array cannot update the wrong information.

Suggestions

none