No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade
Knowledge Base

FAQ-How to solve the problem that the FC card of VTL3500 falis to connect the switch

Publication Date:  2012-10-15  |   Views:  161  |   Downloads:  0  |   Author:  SU1000864011  |   Document ID:  EKB1000017140

Contents

Issue Description

On some site, it fails to connect VTL3500 by IBM switch, it displays L-port, cannot recognize in switch state.

Alarm Information

none

Handling Process

1. Modify FC card mode to loop.
2. Login in VTL3500 command line via SSH, type in vi /usr/local/vtl/etc/fshba.conf, modify connection_option-hba0=0 ,connection_option-hba1=0
#======================================================================
#connection_option-hbaX=1 (PointToPoint) #comment=topology to use 0-LOOP , 1-PointToPoint
#range=0(LOOP) - 1(PointToPoint) - 2(Loop Preferred, then P2P) #============================
connection_option-hba0=1 ---->try 0
connection_option-hba1=1----->try 0
connection_option-hba2=1
connection_option-hba3=1
connection_option-hba4=1
3. Reoot.
4. Check it in the switch and it is normal.

Root Cause

The mode of FC card is not compatible with IBM switch.

Suggestions

  If there is switch problems, try the method above.