The cluster cannot switch automatically caused by the collision between VCS disk reservation and multipathing driver

Publication Date:  2012-10-16  |   Views:  239  |   Downloads:  0  |   Author:  SU1000864011  |   Document ID:  EKB1000017241

Contents

Issue Description

Some site uses double hosts(SUSE Linux9 sp3)+ double FC switch+S3100 storage to make cluster. When the two optical fibers between one of the hosts and the storage are in fault, VCS cluster does not switch automatically, and lead to operation cut.

Alarm Information

There is “ [RAIDarray.mpp]DBArray:0/1:any:0: mppVhba command 0 failure - RESERVATION CONFLICT. vcmnd SN 9104566” error in message log of the host.

Handling Process

Cancel the disk reservation configuration in VCS.

Root Cause

The problem is lead by the collision between VCS disk reservation strategy and RDAC multipathing software. If VCS is configured disk reservation strategy, it will collide with RDAC, and lead to the problem.

Suggestions

Don’t configure disk reservation when there is multipathing software.