No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-The quantity of S9300 configuring vlan-stacking

Publication Date:  2012-10-16 Views:  118 Downloads:  0

Issue Description

Q:
What is the quantity of S9300 configuring vlan-stacking?

Alarm Information

NULL

Handling Process

A:
S9300 device configures vlan-stacking flexible QinQ base interface, it will not take acl resource but only vlan-stacking resource. The different board limit the vlan-stacking number. It does not relate to whether the device is SA type or EA type board, device that 48 ports board supports 8K quanlity vlan-stacking, device that 24 ports board supports 768 quanlity vlan-stacking, it will calculate vlan information independently to different ports, the same inter vlan of 2 ports take 2 vlan-stacking resource. If exceed the board standard, device will report the following information:
Error: Single VLAN-MAPPING or VLAN-STACKING is canceled because the number of VLAN-MAPPING or VLAN-STACKING entries has reached the maximum.

Root Cause

NULL

Suggestions

Confirm the specific inter vlan configuration when configure flexible QinQ, and save the vlan-stacking resource.

END