Add MCU to SMC2

Publication Date:  2013-03-06 Views:  698 Downloads:  0

Issue Description

MCU VP6850

Alarm Information

you can't add the MCU to SMC.2

Handling Process

1- Use numbers in "gk prefix" field  in SMC2.0 web page not a characters . For Example "010"、“0086”and so on. Check the attached image.



2-Let the prefix is same at the MCU and the GK.[check the attached image]
3-check the “Access password” . [The default access password is “123456” ].
4-Check if the MCU is registered on GK or not .
5-You can delete the “GK Authentication Password” if you are not using an authentication .[Keep the field empty ]

Root Cause

the GK prefix is wrong . it must be number

Suggestions

the Password of the authentication and prefixes must be sam on the MCU and the GK