Issue Description
The controller B is faulty and not functioning From the Event viewer we will observe Error code (11) on controller,
Alarm Information
The controller B reported error code 11 at 2013-08-17,
2013-08-17 04:47:02 0xe02040004 Major None The controller (controller 0, controller B) is faulty. The error code is ( 11). Step 1 Contact technical support engineers for further handling.
![]()
Handling Process
1. collect the logs
2. analyse the logs
3. decode the error code "0xe02040004 Major "
4. log a part replacement request
5. replace the faulty controller
6. check the storage system health.
Root Cause
The controller B reported error code 11 at 2013-08-17,
2013-08-17 04:47:02 0xe02040004 Major None The controller (controller 0, controller B) is faulty. The error code is ( 11). Step 1 Contact technical support engineers for further handling.
it means this controller has PCIE error issue,
we need to raise part replace controller B. request,
controller BOM code: 0305G06K
Part description 成品板单元-S3900-STL1CONT04-SAS控制器单元(1*Intel G1101,8G缓存)
Internal english description S3900,STL1CONT04,SAS Service Processing Controller Unit(1*Intel G1101,8G Cache)
Internal model No. STL1CONT04
External chinese description SAS控制器单元(1*Intel G1101,8G缓存)
External english description SAS Service Processing Controller Unit(1*Intel G1101,8G Cache)
Suggestions
before replacing the controller
1. note down the firmware version of new and old controller
2. ensure you have backup of the existing LUN
3. if possible plan a downtime and power down the storage box and replace the new controller
4. check the system health from ISM console
5. verify that Software version and Firmware version are compitable,
6. verify the LUN connectivity and LUN ownership on new controller