No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Connecting 2 SANs to CX311

Publication Date:  2013-12-09 Views:  322 Downloads:  0

Issue Description

After connecting 2 SANs to the CX311 all the volumes disappeared 

Alarm Information

Alarm Msg: [Wed Aug 21 03:50:38.467 UTC 2013][A][1005.0103][Potential misconfiguration: TF ports of the same port group discovering multiple fabric names.]

Handling Process

customer must use the following topology 


Root Cause

Customer needs to connect 2 FC SANs ( IBM and NetApp) 
Each FC is connected to 2 FC Switchs 
as a result each CX311 is connected to more than 1 FC switch 

CX311 can't be connected except to a single FC switch while working in transparent mode 

Suggestions

None

END