SHDSL 2 pair flapping continuously because of miss-configuration

Publication Date:  2014-02-19  |   Views:  327  |   Downloads:  0  |   Author:  b00745015  |   Document ID:  EKB1000039866

Contents

Issue Description

We got problems with a AR158E on a SDSL 1 wire, the atm port is flapping UP/DOWN. 

[V200R003C01SPC300]
#
interface Atm0/0/0
description SDSL-BRIDGE
shutdown
pvc 8/35
  map bridge Virtual-Ethernet0/0/0
shdsl annex b
shdsl capability g-shdsl

Line was boucing from activated to activating. Signal ranges were normal.

dis dsl inte atm 0/0/0
-------------------------------------------------------------------
  Operating mode                                  :CPE
  Port admin status                               :Active
  Port running status                             :Activated
  Port bind status                                :MPair-2
  Bind group master port                          :0
  Port transmission mode                          :G.991.2 Annex B
  Port power spectral density                     :Symmetric
  Port line probe                                 :Enable
  Line Status of SHDSL port 0
  Current line rate(unit:kbps)                    :0
  Current transmission mode                       :G.991.2 Annex A
  Actual payload line rate(unit:kbps)             :0
  Current modulation mode                         :-
  Current PBO downstream(unit:dB)                 :0.0
  Current PBO upstream(unit:dB)                   :-
  Current loop attenuation downstream(unit:dB)    :0
  Current loop attenuation upstream(unit:dB)      :-
  Current SNR margin downstream(unit:dB)          :0
  Current SNR margin upstream(unit:dB)            :-
  Inventory of SHDSL port 0
  Vendor ID                                       :Infineon
  Vendor mode                                     :SOCRATES
  Vendor serial                                   :4e_2e_1e
EOC version                                     :0
  Standard version                                :8
  Vendor list                                     :-
  Vendor issue                                    :1
  Software code                                   :1.7.5
  Equipment code                                  :-
  Information of other vendor                     :V200R003
  Transmission mode capability                    :G.991.2 Annex A&B
  Current 15 minutes statistic of SHDSL port 0
  Total seconds counted in 15 minutes             :171
  ES count in 15 minutes (unit:Second)            :0
  SES count in 15 minutes (unit:Second)           :0
  CRC anomaly count in 15 minutes                 :0
  LOSW count in 15 minutes (unit:Second)          :0
  UAS count in 15 minutes (unit:Second)           :67


dis dsl inte atm 0/0/01
-------------------------------------------------------------------
  Operating mode                                  :CPE
  Port admin status                               :Active
  Port running status                             :Activating
  Port bind status                                :MPair-2
  Bind group master port                          :0
  Port transmission mode                          :G.991.2 Annex B
  Port power spectral density                     :Symmetric
  Port line probe                                 :Enable
  Current 15 minutes statistic of SHDSL port 1
  Total seconds counted in 15 minutes             :175
  ES count in 15 minutes (unit:Second)            :0
  SES count in 15 minutes (unit:Second)           :0
  CRC anomaly count in 15 minutes                 :0
  LOSW count in 15 minutes (unit:Second)          :0
  UAS count in 15 minutes (unit:Second)           :86

Alarm Information

none.

Handling Process

Run the shdsl bind m-pair 2 pairs enhanced command on the G.SHDSL interface working in ATM mode to set the binding mode to enhanced. For some specific DSLAM board chip we need to force binding mode, otherwise synchronization will fail.
By default, a G.SHDSL interface uses the auto-enhanced mode.

Root Cause

DSLAM device vendor was unknown, most probably there are some incompatibility issues.


Suggestions