No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Attendant Services - Break-In

Publication Date:  2014-06-23 Views:  154 Downloads:  0

Issue Description

*80*TN    is not working according to the document.
*80*TN# is working after test.

Alarm Information

NIL

Handling Process

*80*TN#

Root Cause

Would like to share with you regarding to this Headex guide for U1930 or U1980 of its Attendant Services - Break-In. Here i attach is a screen shot highlighting the issue.

In this guide it show only *80* TN (TN could be any intra-office number) in order to "Break-In" a ongoing conversation. The correct respond is suppose to be *80*TN#. In simple its just missing a "#" symbol step.....

Suggestions

Update the information in latest  documentation. Else to a new user who is configuring may encounter the same problem.

END