SoftCo 9500 failed to make a call as a tandem PBX

Publication Date:  2014-09-24  |   Views:  564  |   Downloads:  0  |   Author:  c00535101  |   Document ID:  EKB1000053454

Contents

Issue Description

Network topology:  12000PBX1----(SIPTK)----SoftCo 9500----(R2)----PBX214000
When 12000 make a call to 14000, hear “the number you dialed doesn’t exit”

Alarm Information

No

Handling Process

1、 Check the prefix and number change configuration on each PBX, PBX1 and SoftCo 9500 have 14 local prefix, the local prefix bundling to the correct office, PBX2 have 14 inter prefix, the number change is reasonable.
2、 Collect SoftCo 9500 call logs, and check, then found SoftCo analysis the called number route failed.
[ccm.c 33180][dwCCMNo=   29] Fail to query callee number analysis table.
3、 Check the configuration of prefix 14 on SoftCo 9500, then found the parameter “If4PSTN” was NO, when SoftCo as a tandem PBX, this parameter should be YES, to allow the outgoing call pass.

Root Cause

Configuration problem, when configured a subpbx and the prefix didn’t bundling one subpbx. The value of “If4PSTN” of a prefix will be No. 

Solution

Execute command “config modify prefix dn 14 if4pstnprefix yes” to modify the prefix attribute, then test and the issue was resolved. 

Suggestions

Default the value of “If4PSTN” of a prefix is YES, only except when SoftCo have configured a subpbx and the prefix didn’t bundling one subpbx.