index values problem , MRTG issue

Publication Date:  2014-10-31 Views:  217 Downloads:  0

Issue Description

index values are changing after every boot.
also , if customer create new vlanif , index value for fixed interafecs will be changed.

Alarm Information

MRTG server not able to get the graph for each device.

everytime cusotmer has to poll the device.

Handling Process

after confirmation , before v1r6 index  values are chaning

but in v2r1 index value is fixed. so customer need upgrade it .

Root Cause

after confirmation , before v1r6 index  values are chaning

but in v2r1 index value is fixed. so customer need upgrade it .

Solution

customer has to delete all vlanif interafce after upgradation .

Execute following cmds

[Huawei]diag
[Huawei-diag] reset constant-ifindex map
[Huawei-diag]quit
[Huawei]quit
<Huawei>save
<Huawei>reboot

Suggestions

before configuration , upgrade to v2r1 or upper version .

then create new vlanif interafecs.

END