MA562x device panel missing in U2000 V100R008

Publication Date:  2014-11-03 Views:  1284 Downloads:  0

Issue Description

MA562x device panel missing

Solution

1. syncronize the devices
2. check the logs : BmsAccess_xxxxx
3. 7340033.pod

from the logs:CLicensePro::DeleteResFromDBWhenLicenseLack


check the device license and update the same

no license should be over utilized, if there is some componenet that is overflow apply for the license and upload and follow the below step to update the status.

1. stop and start  BmsCommon,BmsAccess, security in U2000 System Monitor