The DataStation Failed to Start in the SuSE Linux Operating System

Publication Date:  2015-06-30  |   Views:  737  |   Downloads:  0  |   Document ID:  EKB1000080800

Contents

Issue Description

The DataStation fails to start, with the following error message:
terminate called after throwing an instance of 'CZXException'.

Handling Process

Step 1 Log in to the DataStation server as the root user.
Step 2 Run the dos2unix *.txt command to convert all the DataStation configuration files to the Unix format.

Root Cause

The ASCII code script file is saved in DOS format on the server. As a result, when the DataStation starts up, the script file cannot be read.