Publication Date:  2017-10-18  |   Views:  873  |   Downloads:  3  |   Author:  m84067882  |   Document ID:  EKB1000952012

Contents

Issue Description

The customer wants to clear an alarm in eOMC. Please keep in mind that the alarm will reappear after the eNodeB will be restarted. 

Solution

To query the serial number of the active alarm to be cleared, run the LST ALMAF command:


The next step is to acknowledge (ACK) the alarm in alarm monitor tab -> right click on the alarm -> ACK



 If you want to hide/clear the alarm you need run the command: RMV ALMFLT and write the serial no which indicates the serial number of an alarm, which is arranged on the basis of the time when the alarm is generated. The serial number of an alarm is the only index in the alarm logs (the below picture). 


Press Execute buttom and accept. The alarm will be cleared.