Adding an HBA to the Backup Product VTL6900-AIO Causes VTL Services to Stop

Publication Date:  2018-10-17  |   Views:  676  |   Downloads:  0  |   Document ID:  EKB1001911130

Contents

Issue Description

A VTL6900-AIO is deployed at a site. After a QLogic HBA is added, VTL services cannot be started.

Handling Process

1. In the address box of a browser, enter http://IP or https://IP:httpsport, where IP indicates the IP address of the eth2 management network port on the VTL server, and httpsport indicates the HTTPS service port that cannot be accessed.

2. Check the status of the VTL's underlying operating system. It is found that all services are in the Stop state.

[root@VTL6900 ~]# vtl status

Huawei VTL Server v8.10 (Build 9137)
Copyright (c) 2003-2014 FalconStor Software. All Rights Reserved.

Status of VTL Configuration Module                         [STOP]
Status of VTL Base Module                                  [STOP]
Status of VTL HBA Module                                   [STOP]
Status of VTL Authentication Module                        [STOP]
Status of VTL Server (Compression) Module                  [STOP]
Status of VTL Server (Cipher) Module                       [STOP]
Status of VTL Server (HiFn HW Compression) Module          [STOP]
Status of VTL Server (FSNBase) Module                      [STOP]
Status of VTL Server (Upcall) Module                       [STOP]
Status of VTL Server (Transport)                           [STOP]
Status of VTL Server (Event) Module                        [STOP]
Status of VTL Server (Path Manager) Module                  [STOP]

3. Run the vtl start command. The command output is as follows:



It is found that a new HBA is added. In addition, the VTL enters the Stop state after being started.

4. In the event of VTL-I, VTL-IS, VTL-SL, and VTL-AIO specifications, load the QLogic HBA driver. Before loading or uninstalling an HBA driver, disable the target mode of the Fibre Channel port and stop the services of the VTL service system. You are advised to uninstall the existing HBA driver before loading an HBA driver.

4.1 The example of using the vtl stop all command is as follows:
[root@VTL6900 ~]# vtl stop all

Huawei VTL Server v8.10 (Build 9137)
Copyright (c) 2003-2015 FalconStor Software. All Rights Reserved.

Detaching all Virtual Devices
We recommend stopping all vtl client services prior to shutdown.
Otherwise, data loss may occur.
Are you sure you want to continue? (y/n) [n]: y
Continuing with Detaching all Virtual Devices
Stopping VTL SNMPD Module                                  [  OK  ]
Stopping VTL Failover Module                               [  OK  ]
Stopping VTL Self Monitor Module                           [  OK  ]
Stopping VTL Server IMA Daemon                             [  OK  ]
Stopping VTL OpenStorage Server Module                     [  OK  ]
Stopping VTL Server Resolver Daemon                        [  OK  ]
Stopping VTL RDE Failover Daemon                           [  OK  ]
Stopping VTL Server RDE Daemon                             [  OK  ]
Stopping VTL Server VTL Upcall (32 bit) Daemon             [  OK  ]
Stopping VTL Server VTL Upcall Daemon                      [  OK  ]

4.2 The example of using the vtl configtgt command is as follows:
[root@VTL6900 ~]# vtl configtgt
VTL server supports the following target mode HBAs
NOTE: VTL server only supports one target mode HBA at a time

    qlogic) QLogic HBA
qlogicnpiv) QLogic NPIV HBA
         q) No Fibre Channel support

Select HBA class:  // Enter q to uninstall the existing HBA driver. Enter qlogic or qlogicnpiv to load an HBA driver.

4.3 The example of using the vtl start command is as follows:
[root@VTL6900 ~]# vtl start

Huawei VTL Server v8.10 (Build 9137)
Copyright (c) 2003-2014 FalconStor Software. All Rights Reserved.

Starting VTL Configuration Module                          [RUNNING]
Starting VTL Base Module                                   [RUNNING]
Starting VTL HBA Module                                    [RUNNING]
Starting VTL Authentication Module                         [  OK  ]
Starting VTL Server (Compression) Module                   [  OK  ]
Starting VTL Server (Cipher) Module                        [  OK  ]
Starting VTL Server (HiFn HW Compression) Module           [  OK  ]
Starting VTL Server (FSNBase) Module                       [  OK  ]
Starting VTL Server (Upcall) Module                        [  OK  ]
Starting VTL Server (Transport)                            [  OK  ]
Starting VTL Server (Event) Module                         [  OK  ]
Starting VTL Server (Path Manager) Module                  [  OK  ]
Starting VTL Server (Application)                          [  OK  ]

4.4 The example of using the vtl status command is as follows:
[root@VTL6900 ~]# vtl status

Huawei VTL Server v8.10 (Build 9137)
Copyright (c) 2003-2014 FalconStor Software. All Rights Reserved.

Status of VTL Configuration Module                         [RUNNING]
Status of VTL Base Module                                  [RUNNING]
Status of VTL HBA Module                                   [RUNNING]
Status of VTL Authentication Module                        [RUNNING]
Status of VTL Server (Compression) Module                  [RUNNING]
Status of VTL Server (Cipher) Module                       [RUNNING]
Status of VTL Server (HiFn HW Compression) Module          [RUNNING]
Status of VTL Server (FSNBase) Module                      [RUNNING]
Status of VTL Server (Upcall) Module                       [RUNNING]
Status of VTL Server (Transport)                           [RUNNING]
Status of VTL Server (Event) Module                        [RUNNING]
Status of VTL Server (Path Manager) Module                 [RUNNING]
Status of VTL Server (Application)                         [RUNNING]
Status of VTL Server VTL Upcall Module                     [RUNNING]

5. Log in to the device again. The login is successful.

Root Cause

1. During service startup, the VTL detects that a new HBA is added but fails to load the driver. As a result, other VTL services fail to start, causing a failure to log in to the ISM.

2. In the event of VTL-HA and VTL-HAS specifications, load the QLogic NPIV HBA driver. In the event of VTL-I, VTL-IS, VTL-SL, and VTL-AIO specifications, load the QLogic HBA driver. Before loading or uninstalling an HBA driver, disable the target mode of the Fibre Channel port and stop the services of the VTL service system. You are advised to uninstall the existing HBA driver before loading an HBA driver.

Solution

1. Check whether the version is changed.

2. View each service's status to check whether any service is in the Stop state.

3. Check whether any hardware is added or deleted without following the correct operation procedure.

Suggestions

1. Pay attention to the product version update information. Update software and firmware versions promptly.

2. Analyze both the hardware and software to diagnose problems.