Publication Date: 2018-10-20 | Views: 3363 | Downloads: 0 | Author: t84102067 | Document ID: EKB1001931712
Failure
cause: The loaded file is oversized
SmartAX
MA5600T - SCUN firmware Error while upgrading
The current
version of firmware on the card is:
MA5600T(config)#display version 0/9
Main Board: H801SCUN
---------------------------------------
PCB
Version: H801SCUN VER
D
Base
BIOS Version:
212
Extended
BIOS Version: 120
Software Version:
MA5600V800R010C00
Logic
Version:
(U48)111
MAB
Version: 0001
SubBoard:
PCB
Version: H801CKMC VER
A
FPGA
Version:
132
---------------------------------------
SmartAX
MA5600T - SCUN firmware V800R017C10SPH202.
While
installing this firmware giving the following error:
MA5600T (config)#load packetfile ftp 10.10.0.5 scu_packet.bin
The new packet file will overwrite the old
one
Rollback function will be
disabled
Be sure that the system needn't this
function
Are you sure to load new packet file?
(y/n)[n]:y
Info: Standby board is abnormal, and command of
loading for standby board is impossible
Load (backup,duplicate,...) begins, please wait
and notice the rate of progress Any operation such as reboot or
switchover will cause failure and
Unpredictable result
The loading starts
PARAMETERS: FrameID: 0, SlotID: 9, Position:
-1, Load type: Packet file, Load Object: Active control board
MA5600T (config)#
MA5600T (config)#
The loading fails
PARAMETERS: FrameID: 0, SlotID: 9, Position:
-1, Load type: Packet file, Load Object: Active control board, Failure cause:
The loaded file is oversized
MA5600T (config)#
After renamed the bin file so it had a shorter name as it might cause the problem.
Loading package files
Step 1 Copy
the combined package file to the SFTP directory
Step 2 Load
the combined package file.
Unpacking &
packing loading
Run the load packetfile
command to load the combined package file after repacked.
Smart loading mode
Run the load
packetfile smart command to load the original combined package file.
Load the combined package file.
Method 1: Use
the unpacking&packing tool to unpack the combined package file, repack the
combined package file into a file of a smaller size and then load the file.
Method 2: Use the msart loading mode to load the combined package file automatically
Another option will be using “smart
command” below:
Please use “smart”:
Or use packet_tool to customize the
packet file:
The maximum size of SCUN board -80MB
for the combined package file.