no response from the AF alarm of eCNS 280 Due to Wrong port Configuration

Publication Date:  2019-01-13 Views:  87 Downloads:  0
Issue Description

after eCNS280 integration No response from the AF alarm due to Wrong Configuration of Diam Link  Port. 

Handling Process

check the script of eCNS280,found the localport has config error

Root Cause

configuration error Of Local port  Diamconnection

Solution

after modify the local port of DIAMCONNECTION,the issue is solved.

END