alert in E9000 - alarm ID :0x0743FF27

Publication Date:  2019-03-06 Views:  139 Downloads:  0
Issue Description

There are alarm in HMM "E9000" , detail as below :



Handling Process

for this issue, always caused by network issue , we can follow the alarm suggestion to check step by step , alarm ID :0x0743FF27; 

after check, cable connected to stack port , but not management port . after change the management network cable

to management port , alarm disappeared 


Root Cause

customer connect the wrong port cause this alarm .

Solution

connect management port on MM board then the alarm disappeared .