An Error Occurs When the nat outbound Command Is Configured for GE00/0/0 on an AR509CG-Lc of V200R008C50SPC500

Publication Date:  2019-03-26 Views:  36 Downloads:  0
Issue Description

An error occurs when the nat outbound command is configured for GE00/0/0 on an AR509CG-Lc of V200R008C50SPC500.

Alarm Information
Handling Process

1. Analyze error information. It is found that the NAT outbound configurations exceeded the limit.

2. Check the device configuration. Two nat outbound commands are found.

#

interface Cellular0/0/0

 nat outbound 2998

#

interface GigabitEthernet0/0/4

 nat outbound 2999

#

3. Find that GE0/0/4 is not a physical interface on the AR509CG-Lc. This interface is a reserved virtual interface.

 

Solution

Delete the nat outbound command configured on GE0/0/4 and reference this configuration to GI0/0/0. No error is reported.