FAQ – Services Are Interrupted Within a Short Period of Time After a Terminal Connected to the S5720-52X-SI-AC V200R010C00SPC600 Passes 802.1X Authentication

Publication Date:  2019-07-04 Views:  121 Downloads:  0

Issue Description

Services are interrupted within a short period of time after a terminal connected to the S5720-52X-SI-AC V200R010C00SPC600 passes 802.1X authentication.
Key authentication configuration:
#
authentication-profile name czbank-ts
 dot1x-access-profile dot1x_access_profile
 access-domain czbank-ts force
#
dot1x-access-profile name dot1x_access_profile
 dot1x handshake
#
#
interface GigabitEthernet0/0/4
 authentication-profile czbank-ts
#

Handling Process

#
dot1x-access-profile name dot1x_access_profile
undo dot1x handshake    //Disable the dot1x handshake function.
#

Most terminals do not support the handshake function. Therefore, the xxC device will not receive handshake response packets within the handshake period. As a result, the xx device considers that the terminals are offline, causing service interruption.