Publication Date: 2019-04-16 | Views: 1046 | Downloads: 0 | Document ID: EKB1100012241
NE40E-X3 V600R008C10SPC300 V600R008SPH033
Why are there two ESNs, one for the chassis and the other for the main control
board displayed?
<QHXN-OUT-CRT-HWNE40-2>DIS ESN
ESN of master:210305420610HB000056
ESN of slave:2102355250P0HB000010
< QHXN-OUT-CRT-HWNE40-2>DIS license ESN
ESN: 2102355250P0HB000010,210305420610HB000056
[Rack_1]
[SubRack_1]
/$[ArchivesInfo Version]
/$ArchivesInfoVersion=3.0
[Board Properties]
BoardType=CR5Z2BKPG
BarCode=2102355250P0HB000010
Item=02355250
Description=NetEngine40E-X3,CR5Z2BKPG,NE40E-X3 Integrated AC Chassis
Components, (Including Dual AC Power)
Manufactured=2017-11-08
VendorName=Huawei
IssueNumber=00
CLEICode=
BOM=
[Slot_5]
/$[Board Integration Version]
/$BoardIntegrationVersion=3.0
[Main_Board_0]
/$[ArchivesInfo Version]
/$ArchivesInfoVersion=3.0
[Board Properties]
BoardType=CR52MPUD2
BarCode=210305420610HB000056
Item=03054206
Description=NetEngine40E,CR52MPUD2,Main Processing Unit D2(Including 2G Memory
and 2G USB)
Manufactured=2017-11-17
VendorName=Huawei
IssueNumber=00
CLEICode=
BOM=
After
a license is loaded to the NE40E-X3, the main control board checks the ESN of
the chassis and the ESN in the applied .dat file. If the two ESNs do not match, the device compares the ESN of the
main control board and the ESN in the .dat file. As a result, the BarCode of the chassis and the BarCode of the
main control board are displayed in the display esn command output.
The license loaded to the NE40E-X3 is in the Trial state.
Also,
the ESN in the current license file does not match the BarCode of the chassis.
To
address the problem, load a correct license.
It is confirmed that the problem is caused by an inconsistency between the ESN of the chassis and the ESN in the applied .dat file.