The VCN3020 Is Powered Off Abnormally, the System Cannot Be Accessed, the IP Address of the Service Network Port Is Unreachable, and the Network Adapter Indicator Is Off

Publication Date:  2019-04-20 Views:  111 Downloads:  0

Issue Description

The VCN3020 fails to be accessed due to an unexpected power failure. The IP address of the service network port is unreachable, and the network adapter indicator is off.

Handling Process

1. When you log in to the system through the KVM, the system displays the message "Give root password for maintenance", as shown in the following figure.
2. Enter the password for rooting the system. The page for manually restoring the system file is displayed, as shown in the following figure.
3. Enter the command fsck.ext3 -y /dev/sda* (* indicates the digit 1 to 11).
A total of 11 commands are entered. If the file needs to be repaired, a message will be displayed asking you whether to repair the file. Press Enter (because the suse automatic repair is not available). When another message is displayed, enter y. The partitions that do not need to be repaired are skipped. This process takes about 5 minutes.
4. After the repair is complete, run the reboot command to restart the system.