FAQ-Why Is an Error Message Displayed During CPOS Interface Bundling on an NE40E

Publication Date:  2019-07-28 Views:  112 Downloads:  0

Issue Description

1. When an NE40E V600R008C10SPC300 is configured with MP-Group, the message "the serial and the mp-group is not at the same chip,2" is displayed.


Details are as follows:

interface serial s1/2/5/1:1

link-pro ppp

ppp mp mp-group 1/2/25

the serial and the mp-group is not at the same chip.

2. The CPOS board model is 03030JUA (8-port OC-3c/STM-1c POS-SFP flexible card).

Solution

1. For the 8-port CPOS card, interfaces 0 to 3 correspond to chip 1, and interfaces 4 to 7 correspond to chip 2.

 2. A total of 256 MPs exist. The first 128 MPs are used for chip 1, and the rest 128 MPs are used for chip 2.

Therefore, MP 1/2/25 belongs to chip 1 and interface 5 belongs to chip 2. Therefore, they cannot be bundled. Bundle interface according to the mapping between the chips and MPs.