FAQ - The Status of All Blades on E9000 Was Faulty on eSight

Publication Date:  2019-04-23 Views:  53 Downloads:  0
Issue Description

After an E9000 was connected to eSight, the status of all blades was Faulty. No alarm was generated on the BMC or HMM of the E9000.

Solution

1. Log in to the BMC of the blade and check whether the protocol of the blade is SNMP.


2. Check whether the eSight version is V300R007C00SPC500-SPC505 or V300R008C00SPC200.

If the blade protocol is SNMP and eSight version is V300R007C00SPC500-SPC505 or V300R008C00SPC200, this problem is a known issue. Upgrade eSight to V300R008C00SPC202 to solve this problem.