Due to Memory Alarms on an NE20E-S4 V800R007C10SPC100, Ping to the Local Address Fails

Publication Date:  2019-04-24 Views:  17 Downloads:  0
Issue Description

Version information: V800R007C10SPC100

Networking description: This scenario does not involve other interconnection devices. A patch file needs to be loaded for the device's memory alarms. After the PC is connected, however, the ping operation to the router address fails.

Networking diagram:

Configuration script:

This networking does not involve the configuration script. Therefore, a patch file needs to be loaded. After the PC is connected to the router, commission the basic IP address.

Detailed records of the fault:

Log in to the device to view the memory information.

<BeiJing_NE20E-S4-1> dis memory-usage

Memory utilization statistics at 2017-05-01 19:40:18 218 ms

System Total Memory Is: 2040772 Kbytes

Total Memory Used Is: 878524 Kbytes

Memory Using Percentage Is: 85%

Handling Process

1. Connect the PC to the router. It is found that the PC fails to ping the router's interface address, and the router fails to ping any of the local interface address.

2. Check the memory information on the slave main control board of the router.

   <BeiJing_NE20E-S4-1> dis memory-usage slave 

   Memory utilization statistics at 2017-05-01 20:21:01 410 ms

   System Total Memory Is: 2040772 Kbytes

   Total Memory Used Is: 775476 Kbytes

   Memory Using Percentage Is: 37%

3. Given that the live-network services are not affected, perform a master/slave board switchover (On an internal network, packet loss does not occur if the ping operation is often performed on the internal network addresses of other sites).

Before perform a master/slave switchover on the main control boards, run the slave switchover enable command to enable the forcible switchover function on the master and slave main control boards.

After the slave switchover command is run, the original master main control board is reset and changes to be in the slave state, and the original slave main control board takes over services to become the new master board.

After the slave switchover command is run, run the display switchover state command to check whether the master/slave switchover of the main control boards succeeds.

4. Check the memory usages of the master and slave main control boards. If the memory usages are below 40%, services are normal.

5. Use a PC to ping the router and install the patch NE20E-SV800R007SPH030.PAT to perform an upgrade.

The patch information and memory usage are as follows:

   <BeiJing_NE20E-S4-1> dis patch-information 

   Patch Package Name    :cfcard:/NE20E-SV800R007SPH030.PAT

   Patch Package Version :V800R007SPH030

   Patch Package State   :Running   

   Patch Package Run Time:2017-04-30 20:21:57

   #

   <BeiJing_NE20E-S4-1>dis memory-usage

   Memory utilization statistics at 2017-05-03 12:06:41 701 ms

   System Total Memory Is: 2040772 Kbytes

   Total Memory Used Is: 877496 Kbytes

   Memory Using Percentage Is: 42%

   <BeiJing_NE20E-S4-1>dis memory-usage slave

   Memory utilization statistics at 2017-05-03 12:06:44 954 ms

   System Total Memory Is: 2040772 Kbytes

   Total Memory Used Is: 775604 Kbytes

   Memory Using Percentage Is: 38%

Root Cause

1. This router has not been installed with a patch before. As a result, the memory usage is too high.

===============================================================================

                 display patch-information

===============================================================================

Info: No patch exists.

The current state is: Idle

===============================================================================

                 display startup

===============================================================================

MainBoard:

  Configured startup system software:        cfcard:/V800R007C10SPC100-NE20E.cc

  Startup system software:                   cfcard:/V800R007C10SPC100-NE20E.cc

  Next startup system software:              cfcard:/V800R007C10SPC100-NE20E.cc

  Startup saved-configuration file:          cfcard:/vrpcfg.zip

  Next startup saved-configuration file:     cfcard:/vrpcfg.zip

  Startup paf file:                          default

  Next startup paf file:                     default

  Startup patch package:                     NULL

  Next startup patch package:                NULL

SlaveBoard:

  Configured startup system software:        cfcard:/V800R007C10SPC100-NE20E.cc

  Startup system software:                   cfcard:/V800R007C10SPC100-NE20E.cc

  Next startup system software:              cfcard:/V800R007C10SPC100-NE20E.cc

  Startup saved-configuration file:          cfcard:/vrpcfg.zip

  Next startup saved-configuration file:     cfcard:/vrpcfg.zip

  Startup paf file:                          default

  Next startup paf file:                     default

  Startup patch package:                     NULL

  Next startup patch package:                NULL

2. If the master main control board becomes faulty, the system automatically performs a master/slave switchover. If the master main control board encounters an abnormality, such as threshold-crossing CPU usage or memory usage, a master/slave switchover is not implemented. In this case, run the slave switchover command to perform a master/slave switchover. After that, the memory resources of the master main control board are released. Then, install a patch on the device.

Solution

1. Before a master/slave switchover on the master and slave main control boards, run the slave switchover enable command to enable the forcible switching function on the master and slave main control boards.

2. Run the slave switchover command to perform a master/slave switchover on the master and slave main control boards.

3. The service traffic volume is light when operations are performed at night. In this case, direct monitoring cannot be performed. Run the ping command to perform a test. It is found that no packets are lost during the master/slave switchover of the main control boards.

Suggestions

During daily O&M, you are advised to install a stable patch on the device and view the alarm and log information on the device.