Obtaining the VPC620 SN Through VISCA Commands

Publication Date:  2019-05-14  |   Views:  184  |   Downloads:  0  |   Author:  lWX467101  |   Document ID:  EKB1100015143

Contents

Issue Description

No SN is presented on the exterior of the VPC620.

Handling Process

Use a serial port cable to connect the VPC620 to a PC to obtain the SN.

A serial port cable is required to connect the PC's serial port to the camera's serial port. (One end of the cable is DB9 and the other end is round-headed, as shown in the following figure.)

Step 1. Use the serial port cable to connect the PC's serial port to the camera's COM IN port (that is, the COM port close to the power supply, as shown in the following figure).

Step 2. Use a serial port tool on the PC, such as HyperTerminal and a serial port debugger.

Run the following VISCA commands (serial port type: RS232, baud rate: 9600):

81 ec 5a a5 01 ff