FAQ-Can an Interface of the S9300 Forward Single-tagged Packets After Selective QinQ Is Configured on the Interface

Publication Date:  2019-07-03  |   Views:  232  |   Downloads:  0  |   Document ID:  EKB1100020250

Contents

Issue Description

After QinQ is configured between two switches, the trunk interface cannot forward single-tagged packets are can be directly forwarded originally. The inner VLAN ID and outer VLAN ID in QinQ packets are not the VLAN ID of a single-tagged packet.

After VLAN stacking is configured, the peer 10.1.1.1 cannot be pinged on the VLANIF 99 interface.  

[GigabitEthernet3/0/0]port vlan-stacking vlan 3001 stack-vlan 3000    
[GigabitEthernet3/0/0]ping -c 1000 10.1.1.1                      
    Request time out
    Request time out
    Request time out
    Request time out

Key configuration:

interface Vlanif99
 ip address 10.1.1.2 255.255.255.192
#

interface GigabitEthernet3/0/0
 port hybrid tagged vlan 99
 port hybrid untagged vlan 3000
 port vlan-stacking vlan 3001 stack-vlan 3000

Solution

After VLAN stacking is configured on some cards of the S9300, there is a restraint on single-tagged packets. The detailed information is as follows:


After the port vlan-mapping vlan 99 map-vlan 99 command is run on the interface, the fault is rectified.

interface GigabitEthernet3/0/0

 port hybrid tagged vlan 99
 port hybrid untagged vlan 3000
 port vlan-stacking vlan 3001 stack-vlan 3000
 port vlan-mapping vlan 99 map-vlan 99