Enterprise products, solutions & services
Publication Date: 2020-09-22 | Views: 932 | Downloads: 0 | Author: k84115479 | Document ID: EKB1100054111
2288H V5 - Many HDD failure at the same times.
BIOS Version: 0.99
CPLD Version: 2.07
iBMC Version: 3.20
iBMC screenshot:-
collect server iBMC log.
iBMC log screenshot:-
The server configured with only one RAID card and a 24*2.5 SAS/SATA front disk backplane.
For this disk backplane module, every 8 disks require a RAID card module to manage.
So currently, only slot 0 ~ slot 7 disk can be managed by the RAID card. Other new added disk cannot be managed.
This is the reason why there are alarm for slot 16 ~ slot 21 disks.
As peer current server hardware configuration, it do not support to add more disks.
supporting document:-
The server configured with only one RAID card and a 24*2.5 SAS/SATA front disk backplane.
For this disk backplane module, every 8 disks require a RAID card module to manage.
So currently, only slot 0 ~ slot 7 disk can be managed by the RAID card. Other new added disk cannot be managed.
Add more Raid card to manage more disk, or remove not in used disks.