S5700-28C-HI-24S
Version Mapping
Table 4-993 lists the mapping between the S5700-28C-HI-24S and software versions.
Appearance and Structure
1 |
Power module slot 1 NOTE:
Applicable power modules:
|
2 |
Power module slot 2 NOTE:
Applicable power modules:
|
3 |
ESD jack NOTE:
Before installing or maintaining a switch, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack. |
4 |
One console port |
5 |
One ETH management port |
6 |
Front card slot |
7 |
One USB port |
8 |
Twenty-four 100/1000BASE-X ports |
9 |
Ground screw NOTE:
It is used with a ground cable. The switch has two ground screws, any of which can be used to install a ground cable. |
10 |
Monitoring port NOTE:
The monitoring port monitors the cabinet door, power module, battery power, and power supply of the air conditioner. |
Port Description
100/1000BASE-X port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5700-28C-HI-24S has similar indicators (except service port indicators) to those on the S5700-28C-HI. For details, see Indicator Description.
Power Supply Configuration
The S5700-28C-HI-24S uses pluggable power modules. It can be configured with a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
Heat Dissipation
The S5700-28C-HI-24S has three built-in fans for forced air cooling. The airflow direction is left-to-right.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-997 lists technical specifications of the S5700-28C-HI-24S.
Item |
Description |
---|---|
Memory (RAM) |
512 MB |
Flash |
64 MB |
Mean time between failures (MTBF) |
25.5 years when a 4-port 10GE interface card is configured, 34.8 years when a 2-port 10GE interface card is configured, 36.1 years when a 4-port GE interface card is configured |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
NA |
Power supply surge protection |
|
Dimensions (H x W x D) |
44.4 mm x 442.0 mm x 220.0 mm (1.75 in. x 17.4 in. x 8.7 in.) |
Weight |
|
Stack ports |
|
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz -36 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
80.7 W |
Operating temperature |
-5°C to +55°C (23°F to 131°F) NOTE:
The operating temperature of the switch is -5°C to +50°C (23°F to 122°F) when it uses SFP+ optical modules with 40 km or longer transmission distances. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 60 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
|
Certification |
|
Part number |
02353631 |