S5731-S24T4X (02353AHU/02353AHU-001)
Version Mapping
Table 4-1202 lists the mapping between the S5731-S24T4X chassis and software versions.
Appearance and Structure
Port Description
10/100/1000BASE-T port
10GE SFP+ optical port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5731-S24T4X has similar indicators to those on the S5731-S48P4X except that the S5731-S24T4X does not have a PoE mode indicator. For details, see Indicator Description.
Power Supply Configuration
The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch. However, the power modules with natural heat dissipation and the power modules with fan cannot be used at the same time.
Heat Dissipation
The S5731-S24T4X uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-1207 lists technical specifications of the S5731-S24T4X.
Item |
Description |
---|---|
Memory (RAM) |
2 GB |
Flash |
1 GB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
57.73 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±6 kV |
Power supply surge protection |
|
Dimensions (H x W x D) |
|
Weight (with packaging) |
8.4 kg (18.52 lb) |
Stack ports |
10GE SFP+ ports on the front panel |
RTC |
Supported |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
|
Maximum voltage range |
|
Maximum power consumption (100% throughput, full speed of fans) |
114 W |
Typical power consumption (30% of traffic load, tested according to ATIS standard) |
88 W |
Operating temperature |
-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 57.5 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
02353AHU 02353AHU-001 |