S5731-S8UM16UN2Q
Overview
Item | Details |
---|---|
Description | S5731-S8UM16UN2Q (8*100M/1/2.5/5/10G,16*100M/1/2.5G ports, 2*40GE QSFP ports or 12*100M/1/2.5/5/10G,12*100M/1/2.5G ports, 4*10GE SFP+ ports, PoE++, without power module) |
Part Number | 02354VCD |
Model | S5731-S8UM16UN2Q |
First supported version | V200R022C00 |
Components
1 |
Twelve 100M/1000M/2.5GE BASE-T PoE++ ports (multi-GE ports) |
2 |
Four 100M/1000M/2.5GE BASE-T PoE++ ports or four 100M/1000M/2.5GE/5GE/10GE BASE-T PoE++ ports (multi-GE ports) NOTE:
You can run the set device port-config-mode enable command to change the working mode of multi-GE, SFP+ and QSFP+ ports. By default, the working mode is "8*10G+16*2.5G+2*40G" and can be set to "12*10G+12*2.5G+4*10G".
|
3 |
Eight 100M/1000M/2.5GE/5GE/10GE BASE-T PoE++ ports (multi-GE ports) |
4 |
Four 10GE SFP+ ports NOTE:
You can run the set device port-config-mode enable command to change the working mode of multi-GE, SFP+ and QSFP+ ports. By default, the working mode is "8*10G+16*2.5G+2*40G" and can be set to "12*10G+12*2.5G+4*10G".
|
5 |
Two 40GE QSFP+ ports NOTE:
You can run the set device port-config-mode enable command to change the working mode of multi-GE, SFP+ and QSFP+ ports. By default, the working mode is "8*10G+16*2.5G+2*40G" and can be set to "12*10G+12*2.5G+4*10G".
|
6 |
One ETH management port |
7 |
One console port |
8 |
One USB port |
9 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
10 |
Ground screw NOTE:
It is used with a ground cable. |
11 |
Power module slot 1 NOTE:
Applicable power module: |
12 |
Power module slot 2 NOTE:
Applicable power module: |
13 |
Power module slot 3 NOTE:
Applicable power module: |
- |
- |
Ports
Cable Type (6-a-1 Bundle) |
Multi-GE Port (Different Rates) |
|||
---|---|---|---|---|
100M/1000M |
2.5GE |
5GE |
10GE |
|
Category 5e unshielded twisted pair (Cat5e UTP) |
100 m |
100 m |
Not recommended due to high risk |
Not supported |
Category 5e shielded twisted pair (Cat5e STP) |
100 m |
100 m |
100 m |
Not supported |
Category 6 unshielded twisted pair (Cat6 UTP) |
100 m |
100 m |
100 m Not recommended due to high risk |
Not supported |
Category 6 shielded twisted pair (Cat6 STP) |
100 m |
100 m |
100 m |
Not supported |
Category 6A unshielded twisted pair (Cat6A U/UTP) |
100 m |
100 m |
100 m Not recommended due to high risk |
Not supported |
Category 6A foiled/unshielded twisted pair (Cat6A F/UTP) |
100 m |
100 m |
100 m |
100 m |
Category 6A shielded twisted pair (Cat6A STP) |
100 m |
100 m |
100 m |
100 m |
Category 7 twisted pair (Cat7) |
100 m |
100 m |
100 m |
100 m |
6-a-1 stands for the six-around-one cable bundle mode, with one cable in the center and six cables bundled evenly around it.
- 802.3bz requires that the ALSNR value for alien crosstalk between Ethernet cables be greater than 0, but the standards for Cat5e and Cat6 unshielded twisted pairs do not specify the required ALSNR value. Therefore, such cables may not meet the crosstalk requirement in 802.3bz, causing severe problems such as continuous packet loss or port flapping may occur.
- According the cabling specification TIA TSB-5021, using Cat5e and Cat6 cables for 5G poses high risks.
- Currently, no clear onsite testing or evaluation method is available for checking whether ALSNR of cables conforms to 802.3bz.
If a port works at a rate of 5 Gbit/s and a Cat6 shielded Ethernet cable is used, the Ethernet cable must comply with ISO 11801 PL Class E (+All) or TIA Cat 6 Channel (+All). If a Cat6A shielded Ethernet cable is used, the Ethernet cable must comply with ISO 11801 PL2 Class Ea (+All) or TIA Cat6A Channel (+All). Otherwise, serious problems such as continuous packet loss or interface flapping may occur.
If a port works at a rate of 10 Gbit/s and a Cat6A shielded Ethernet cable is used, the Ethernet cable must comply with ISO 11801 PL2 Class Ea (+All) or TIA Cat6A Channel (+All). Otherwise, serious problems such as continuous packet loss or interface flapping may occur.
If Cat5e and Cat6 unshielded twisted pairs do not meet the 5G requirement, you are advised to replace them with shielded twisted pairs or reduce the rate of ports to 2.5G.
If Cat5E, Cat6, or Cat6A unshielded twisted pairs are used on electrical ports working at 10 Gbit/s, severe problems such as continuous packet loss or port flapping may occur.
Port | Connector Type | Description | Available Components |
---|---|---|---|
100M/1000M/2.5GE BASE-T PoE++ port (multi-GE port) | RJ45 | A 100M/1000M/2.5GE BASE-T port (multi-GE port) sends and receives service data at 100 Mbit/s, 1 Gbit/s, 2.5 Gbit/s. The port supports the PoE function. |
If the 2.5 Gbit/s speed is required, the port must use an Ethernet cable of Cat5e or higher category. |
100M/1000M/2.5GE/5GE/10GE BASE-T PoE++ port (multi-GE port) | RJ45 | A 100M/1000M/2.5GE/5GE/10GE BASE-T port (multi-GE port) sends and receives service data at 100 Mbit/s, 1 Gbit/s, 2.5 Gbit/s, 5 Gbit/s, or 10 Gbit/s. The port supports the PoE function. |
If the 2.5 Gbit/s or 5 Gbit/s speed is required, the port must use an Ethernet cable of Cat5e or higher category. If the 10 Gbit/s speed is required, the port must use an Ethernet cable of Cat6A F/UTP or higher category. |
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
40GE SFP+ optical port | QSFP+ | A 40GE QSFP+ optical port sends and receives service traffic at 40 Gbit/s. A 40GE QSFP+ optical port can be split into four 10GE ports. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. |
|
USB port | USB 2.0 Type A | The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives. |
USB flash drive |
Indicators and Buttons
The S5731-S8UM16UN2Q has the same types of indicators as the S5731-S24UN4X2Q. For details, see the S5731-S24UN4X2Q.
Power Supply System
The switch is a PoE switch and supports three power module slots, each of which can have a 1000 W PoE or 600 W PoE power module installed. Pluggable AC and DC PoE power modules can be used together in the same switch.
Power Module 1 |
Power Module 2 |
Power Module 3 |
Available PoE Power |
Maximum Number of Ports (Fully Loaded) |
---|---|---|---|---|
1000 W AC (220 V) |
– |
– |
778 W |
|
1000 W AC (110 V) |
– |
– |
688 W |
|
1000 W DC |
– |
– |
778 W |
|
600 W AC (220 V) |
– |
– |
441 W |
|
600 W AC (110 V) |
– |
– |
156 W |
|
1000 W AC (220 V) 1000 W DC |
1000 W AC (220 V) 1000 W DC |
– |
1678 W |
|
1000 W AC (110 V) 1000 W DC |
1000 W AC (110 V) |
– |
1498 W |
|
600 W AC (220 V) |
600 W AC (220 V) |
– |
998 W |
|
600 W AC (110 V) |
600 W AC (110 V) |
– |
441 W |
|
1000 W AC (220 V) 1000 W DC |
600 W AC (220 V) |
– |
1318 W |
|
1000 W AC (220 V) 1000 W DC |
1000 W AC (220 V) 1000 W DC |
1000 W AC (220 V) 1000 W DC |
2268 W |
|
600 W AC (220 V) |
600 W AC (220 V) |
600 W AC (220 V) |
1581 W |
|
1000 W AC (220 V) 1000 W DC |
1000 W AC (220 V) 1000 W DC |
600 W AC (220 V) |
2218 W |
|
1000 W AC (220 V) 1000 W DC |
600 W AC (220 V) |
600 W AC (220 V) |
1858 W |
|
1000 W AC (110 V) 1000 W DC |
1000 W AC (110 V) 1000 W DC |
1000 W AC (110 V) |
2268 W |
|
600 W AC (110 V) |
600 W AC (110 V) |
600 W AC (110 V) |
726 W |
|
When a switch has multiple power modules installed, the multiple power modules work in redundancy mode to provide power for the chassis and in load balancing mode to provide power for PDs.
Heat Dissipation System
The switch has two built-in fans for forced air cooling. Air flows in from the left and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 454.0 mm (1.72 in. x 17.4 in. x 17.87 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 6.83 kg (15.06 lb) |
Weight with packaging [kg(lb)] | 9.81 kg (21.63 lb) |
Typical power consumption [W] | 126 W |
Typical heat dissipation [BTU/hour] | 429.93 BTU/hour |
Maximum power consumption [W] |
|
Maximum heat dissipation [BTU/hour] |
|
Static power consumption [W] | 81 W |
MTBF [year] | 54.08 year |
MTTR [hour] | 2.22 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | Three 600 W AC PoE power modules with 30% load: 50.50 dBA Three 1000 W AC PoE power modules with 30% load: 52.50 dBA Three 1000 W DC PoE power modules with 30% load: 52.50 dBA |
Noise at normal temperature (acoustic pressure) [dB(A)] | Three 600 W AC PoE power modules with 30% load: 36.82 dBA Three 1000 W AC PoE power modules with 30% load: 38.82 dBA Three 1000 W DC PoE power modules with 30% load: 38.82 dBA |
Number of card slots | 0 |
Number of power slots | 3 |
Number of fans modules | 2 |
Redundant power supply | 1+1+1 Pluggable AC and DC power modules can be used together in the same switch. |
Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory | 2 GB |
Flash memory | 1 GB in total. To view the available flash memory size, run the display version command. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] |
|
Types of fans | Built-in |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction | Air intake from the front and left and air exhaust from the rear |
PoE | Supported |
Certification | EMC certification Safety certification Manufacturing certification |