S5736-S48S4X-A
Overview
Item | Details |
---|---|
Description | S5736-S48S4X-A base (48*GE SFP ports, optional RTU upgrade to 10G, 4*10GE SFP+ ports, AC power supply, front access) |
Part Number | 98011606 |
Model | S5736-S48S4X-A |
First supported version | V200R020C30 |
Components
1 |
Forty-eight 1000BASE-X ports NOTE:
A RTU license (L-P1GUPG10G-S57S) can be loaded to increase the port rate to 10 Gbit/s. |
2 |
Four 10GE SFP+ optical ports |
3 |
One console port |
4 |
One ETH management port |
5 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
6 |
AC socket NOTE:
It is used with an AC power cable. |
7 |
Ground screw NOTE:
It is used with a ground cable. |
- |
- |
Ports
Indicators and Buttons
No. |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
- |
Service port indicator |
Green |
Off |
The port is not connected or has been shut down. |
Steady on |
A link has been established on the port. |
||||
Yellow |
Off |
The port is not sending or receiving data. |
|||
Blinking |
The port is sending or receiving data. |
||||
2 |
PWR |
Power module indicator |
- |
Off |
The switch is powered off. |
Green |
Steady on |
The system power supply is normal. |
|||
3 |
SYS |
System status indicator |
- |
Off |
The system is not running. |
Green |
Fast blinking |
The system is starting. |
|||
Green |
Steady on |
During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds. |
|||
Green |
Slow blinking |
The system is running normally. |
|||
Red |
Steady on |
The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated. |
|||
4 |
MST |
Stack indicator |
- |
Off |
The switch is not the master switch in a stack. |
Green |
Blinking |
The switch is the master switch in a stack or a standalone switch. |
|||
5 |
ID |
ID indicator |
- |
Off |
The ID indicator is not used (default state). |
Blue |
Steady on |
The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. |
|||
6 |
L/A |
ETH port indicator |
- |
Off |
The ETH port is not connected. |
Green |
Steady on |
The ETH port is connected. |
|||
Green |
Blinking |
The Eth port is sending or receiving data. |
Power Supply System
The switch has a built-in AC power module and does not support pluggable power modules.
Heat Dissipation System
The switch has three built-in fans for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 228.0 mm (1.72 in. x 17.4 in. x 9.0 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90 mm × 555 mm × 345 mm (3.54 in. x 21.85 in. x 13.58 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 3.6 kg (7.9 lb) |
Weight with packaging [kg(lb)] | 4.7 kg (10.36 lb) |
Typical power consumption [W] | 87 W |
Typical heat dissipation [BTU/hour] | 296.85 BTU/hour |
Maximum power consumption [W] | 111 W |
Maximum heat dissipation [BTU/hour] | 378.74 BTU/hour |
Static power consumption [W] | 39 W |
MTBF [year] | 41.97 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 56.8 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 44.8 dB(A) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 3 |
Redundant power supply | Not supported |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | AC built-in |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | 6.0 A |
Memory | 2 GB |
Flash memory | 1 GB in total. To view the available flash memory size, run the display version command. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Not supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | - |
Power supply surge protection [kV] | ±6 kV in differential mode, ±6 kV in common mode |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left and front, air exhaustion from right |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |