S5731S-S32ST4X-A (98011814-001)
Overview
Item | Details |
---|---|
Description | S5731S-S32ST4X Bundle(8*10/100/1000BASE-T ports, 24*GE SFP ports, 4*10GE SFP+ ports, with AC power supply) |
Part Number | 98011814-001 |
Model | S5731S-S32ST4X-A |
First supported version | V200R021C10SPC600 |
Components
1 |
Eight 10/100/1000BASE-T ports |
2 |
Twenty-four 100/1000BASE-X ports |
3 |
Four 10GE SFP+ ports |
4 |
One console port |
5 |
One ETH management port |
6 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
7 |
Ground screw NOTE:
It is used with a ground cable. |
8 |
Power module slot 1 |
9 |
Power module slot 2 |
- |
- |
Ports
Port | Connector Type | Description | Available Components |
---|---|---|---|
10/100/1000BASE-T port | RJ45 | A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s. | |
100/1000BASE-X port | SFP | A 100/1000BASE-X port can send and receive data at 100 Mbit/s or 1000 Mbit/s. | |
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. |
Indicators and Buttons
No. |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
PWR1 |
Power module indicator |
- |
Off |
No power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally. |
Green |
Steady on |
A power module is installed in power module slot 1 and is working normally. |
|||
Yellow |
Steady on |
The switch has two power modules installed. Any of the following situations occurs in power module slot 1:
|
|||
2 |
PWR2 |
Power module indicator |
- |
Off |
No power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally. |
Green |
Steady on |
A power module is installed in power module slot 2 and is working normally. |
|||
Yellow |
Steady on |
The switch has two power modules installed. Any of the following situations occurs in power module slot 2:
|
|||
3 |
SYS |
System status indicator |
- |
Off |
The system is not running. |
Green |
Fast blinking |
The system is starting. |
|||
Green |
Steady on |
During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds. |
|||
Green |
Slow blinking |
The system is running normally. |
|||
Red |
Steady on |
The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated. |
|||
4 |
MST |
Stack indicator |
- |
Off |
The switch is not the master switch in a stack. |
Green |
Blinking |
The switch is the master switch in a stack or a standalone switch. |
|||
5 |
ID |
ID indicator |
- |
Off |
The ID indicator is not used (default state). |
Blue |
Steady on |
The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. |
|||
6 |
- |
Service port indicator (electrical port) |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|||
Blinking |
The port is sending or receiving data. |
||||
7 |
- |
Service port indicator (optical port) NOTE:
If a power failure occurs on a device's PCB board, indicators of the last four optical ports on the device's front panel blink green cyclically at an interval of 1 second, with each indicator illuminating for 0.25 seconds. |
Green |
Off |
The port is not connected or has been shut down. |
Steady on |
A link has been established on the port. |
||||
Yellow |
Off |
The port is not sending or receiving data. |
|||
Blinking |
The port is sending or receiving data. |
||||
8 |
L/A |
ETH port indicator |
- |
Off |
The ETH port is not connected. |
Green |
Steady on |
The ETH port is connected. |
|||
Green |
Blinking |
The Eth port is sending or receiving data. |
Power Supply System
The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch. However, the power modules with natural heat dissipation and the power modules with fan cannot be used at the same time.
Heat Dissipation System
The switch has three built-in fans for forced air cooling. Air flows in from the left, right, and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.4 in. x 17.64 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 5.68 kg (12.52 lb) |
Weight with packaging [kg(lb)] | 8.21 kg (18.10 lb) |
Typical power consumption [W] | 73.56 W |
Typical heat dissipation [BTU/hour] | 250.99 BTU/hour |
Maximum power consumption [W] | 104.82 W (150 W AC or 180 W DC) 119.23 W (600 W AC) |
Maximum heat dissipation [BTU/hour] | 357.66 (150 W AC or 180 W DC) 406.82 (600 W AC) |
Static power consumption [W] | 44.5 W |
MTBF [year] | 71.54 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 45.47 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 31.79 dB(A) |
Number of card slots | 0 |
Number of power slots | 2 |
Number of fans modules | 3 |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together. |
Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory | 2 GB |
Flash memory | 1 GB in total. To view the available flash memory size, run the display version command. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Not supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] |
|
Types of fans | Built-in |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction | Air intake from left, front, and right and air exhaust from rear |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |