S5731-S32ST4X-D (98011810)
Overview
Item | Details |
---|---|
Description | S5731-S32ST4X-D(8*10/100/1000BASE-T ports, 24*GE SFP ports, 4*10GE SFP+ ports, DC power, front access) |
Part Number | 98011810 |
Model | S5731-S32ST4X-D |
First supported version | V200R021C01 |
Components
1 |
Eight 10/100/1000BASE-T ports |
2 |
Twenty-four 100/1000BASE-X ports |
3 |
Four 10GE SFP+ ports |
4 |
One console port |
5 |
One ETH management port |
6 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
7 |
DC power terminal NOTE:
It is used with DC Power Cable. |
8 |
Ground screw NOTE:
It is used with a ground cable. |
Ports
Port | Connector Type | Description | Available Components |
---|---|---|---|
10/100/1000BASE-T port | RJ45 | A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s. | |
100/1000BASE-X port | SFP | A 100/1000BASE-X port can send and receive data at 100 Mbit/s or 1000 Mbit/s. | |
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. |
Indicators and Buttons
The S5731-S32ST4X-D has the same types of indicators as the S5731-S32ST4X-A. For details, see the S5731-S32ST4X-A.
Power Supply System
The switch has a built-in DC power module and does not support pluggable power modules.
Heat Dissipation System
The switch has two built-in fans for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.40 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 236.0 mm (1.72 in. x 17.40 in. x 9.29 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90 mm x 550 mm x 355 mm (3.54 in. x 21.65 in. x 13.98 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 2.98 kg (6.57 lb) |
Weight with packaging [kg(lb)] | 4.34 kg (9.57 lb) |
Typical power consumption [W] | 69.46 W |
Typical heat dissipation [BTU/hour] | 237.00 BTU/hour |
Maximum power consumption [W] | 93.39 W |
Maximum heat dissipation [BTU/hour] | 318.66 BTU/hour |
Static power consumption [W] | 41.42 W |
MTBF [year] | 32.56 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 41.42 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 27.74 dB(A) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 2 |
Redundant power supply | Not supported |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | DC built-in |
Rated input voltage [V] | –48 V DC to –60 V DC |
Input voltage range [V] | –38.4 V DC to –72 V DC |
Maximum input current [A] | 6 A |
Memory | 2 GB |
Flash memory | The physical space is 1 GB. You can run the display version command to view the actual available space. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Not supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | ±2 kV in differential mode; ±4 kV in common mode |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left and front, air exhaustion from right |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |