S5700-52C-PWR-SI
Version Mapping
Table 4-474 lists the mapping between the S5700-52C-PWR-SI and software versions.
Appearance and Structure
1 |
Forty-eight PoE+ 10/100/1000BASE-T ports |
2 |
One console port |
3 |
One ETH management port |
4 |
One USB port |
5 |
Front card slot |
6 |
ESD jack NOTE:
Before installing or maintaining a switch, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack. |
7 |
Rear card slot NOTE:
Card supported: |
8 |
Fan slot NOTE:
Applicable fan module: |
9 |
Power module slot 2 NOTE:
Applicable power modules:
|
10 |
Power module slot 1 NOTE:
Applicable power modules:
|
Port Description
10/100/1000BASE-T port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5700-52C-PWR-SI has the same types of indicators as the S5700-28C-PWR-SI. For details, see Indicator Description.
Power Supply Configuration
The S5700-52C-PWR-SI is a PoE switch. It has two power module slots, each of which can have a 500 W or 250 W power module installed. A power module can provide 369.6 W or 123.2 W of PoE power for powered devices (PDs). Table 4-478 lists its power supply configurations.
Power Module 1 |
Power Module 2 |
Available PoE Power |
Maximum Number of Ports (Fully Loaded) |
---|---|---|---|
250 W |
– |
123.2 W |
|
500 W |
– |
369.6 W |
|
250 W |
250 W |
246.4 W |
|
500 W |
500 W |
739.2 W |
|
When a switch has two power modules installed, the two power modules work in redundancy mode to provide power for the chassis and in load balancing mode to provide power for PDs.
Heat Dissipation
The S5700-52C-PWR-SI uses pluggable fan modules for forced air cooling. Air flows in from the left and right sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-479 lists technical specifications of the S5700-52C-PWR-SI.
Item |
Description |
---|---|
Memory (RAM) |
256 MB |
Flash |
32 MB |
Mean time between failures (MTBF) |
50.4 years when a 2-port 10GE interface card is configured, 68.6 years when a 4-port GE front card is configured, 35.58 years when a 4x10GE front card is configured |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±1 kV |
Power supply surge protection |
±2 kV in differential mode, ±4 kV in common mode |
Dimensions (H x W x D) |
43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.) |
Weight |
|
Stack port |
Two stack ports available on each stack card |
RPS |
Not supported |
PoE |
Supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum power consumption (100% throughput, 100% PoE loads, full speed of fans) |
917 W (system power consumption: 177 W, PoE: 740 W) |
Operating temperature |
0°C to 50°C (32°F to 122°F) |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 45 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
02354135 |