S5735S-L48T4S-MA
Version Mapping
Table 4-1866 lists the mapping between the S5735S-L48T4S-MA chassis and software versions.
Appearance and Structure
Port Description
10/100/1000BASE-T port
1000BASE-X port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5735S-L48T4S-MA has similar indicators to those on the S5735-L12P4S-A except that the S5735S-L48T4S-MA does not have a PoE mode indicator. For details, see Indicator Description.
Power Supply Configuration
The S5735S-L48T4S-MA has a built-in AC power module and does not support pluggable power modules.
Heat Dissipation
The S5735S-L48T4S-MA has one built-in fan for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-1871 lists technical specifications of the S5735S-L48T4S-MA.
Item |
Description |
---|---|
Memory (RAM) |
1 GB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
46.36 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±7 kV |
Power supply surge protection |
±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) |
|
Weight (with packaging) |
4.42 kg (9.75 lb) |
Stack ports |
Any 10/100/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions) |
RTC |
Not supported |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
|
Maximum voltage range |
|
Maximum power consumption (100% throughput, full speed of fans) |
53 W |
Typical power consumption (30% of traffic load)
|
37 W |
Operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
Short-term operating temperature |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 53.3 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
98010971 |