S5700-28C-HI
Version Mapping
Table 4-985 lists the mapping between the S5700-28C-HI and software versions.
Appearance and Structure
1 |
Power module slot 1 NOTE:
Applicable power modules:
|
2 |
Power module slot 2 NOTE:
Applicable power modules:
|
3 |
ESD jack NOTE:
Before installing or maintaining a switch, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack. |
4 |
One console port |
5 |
One ETH management port |
6 |
Front card slot |
7 |
One USB port |
8 |
Twenty-four 10/100/1000BASE-T ports |
9 |
Ground screw NOTE:
It is used with a ground cable. The switch has two ground screws, any of which can be used to install a ground cable. |
10 |
Monitoring port NOTE:
The monitoring port monitors the cabinet door, power module, battery power, and power supply of the air conditioner. |
Port Description
10/100/1000BASE-T port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
Number |
Indicator/Button |
Color |
Description |
---|---|---|---|
1 |
PWR1: power supply indicator |
- |
Off: No power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally. |
Green |
Steady on: A power module is installed in power module slot 1 and is working normally. |
||
Red |
Steady on: The switch has two power modules installed. Any of the following situations occurs in power module slot 1:
|
||
2 |
PWR2: power supply indicator |
- |
Off: No power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally. |
Green |
Steady on: A power module is installed in power module slot 2 and is working normally. |
||
Red |
Steady on: The switch has two power modules installed. Any of the following situations occurs in power module slot 2:
|
||
3 |
SYS: system status indicator |
- |
Off: The system is not running. |
Green |
Indicator states and meaning in V100R006 version:
Indicator states and meaning in V200R001 and later versions:
|
||
Yellow |
|
||
Red |
|
||
4 |
MODE: mode indicator |
- |
Off: The service port indicators are in the status mode (default). In the status mode, the service port indicator shows the port link or activity state. |
Green |
Steady on: The service port indicators show the port speed. After 45 seconds, the service port indicators automatically restore to the status mode. |
||
Red |
Steady on: The service port indicators show the stack ID of the switch. After 45 seconds, the service port indicators automatically restore to the status mode. |
||
5 |
Mode switch button |
- |
In versions earlier than V200R003C00:
In V200R003C00 and later versions:
If you do not press the button within 45 seconds, the mode indicator restores to the default mode. |
6 |
Service port indicator |
Meanings of service port indicators vary in different modes. For details, see Table 4-990 and Table 4-991. |
|
7 |
ETH indicator |
Green |
|
Display Mode |
Color |
Status |
Description |
---|---|---|---|
Status |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|
Green |
Blinking |
The port is sending or receiving data. |
|
Speed |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
10M/100M/1000M port: The port is operating at 10/100 Mbit/s. 1000M/10GE port: The port is operating at 1000 Mbit/s. |
|
Green |
Blinking |
10M/100M/1000M port: The port is operating at 1000 Mbit/s. 1000M/10GE port: The port is operating at 10 Gbit/s. |
|
Stack |
- |
Off |
Port indicators do not show the stack ID of the switch. |
Green |
Steady on |
The switch is not the master switch in a stack.
|
|
Green |
Blinking |
The switch is the master switch in a stack.
|
Display Mode |
Color |
Status |
Description |
---|---|---|---|
Status |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|
Yellow |
Blinking |
The port is sending or receiving data. |
|
Speed |
- |
Off |
The port is not connected or has been shut down. |
Green and yellow |
Steady on |
10M/100M/1000M port: The port is operating at 10/100 Mbit/s. 100M/1000M port: The port is operating at 100 Mbit/s. |
|
Green and yellow |
Blinking |
10M/100M/1000M port: The port is operating at 1000 Mbit/s. 100M/1000M port: The port is operating at 1000 Mbit/s. |
|
Stack |
- |
Off |
Port indicators do not show the stack ID of the switch. |
Green and yellow |
Steady on |
The switch is not the master switch in a stack.
|
|
Green and yellow |
Blinking |
The switch is the master switch in a stack.
|
Power Supply Configuration
The S5700-28C-HI uses pluggable power modules. It can be configured with a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
Heat Dissipation
The S5700-28C-HI has three built-in fans for forced air cooling. The airflow direction is left-to-right.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-992 lists technical specifications of the S5700-28C-HI.
Item |
Description |
---|---|
Memory (RAM) |
512 MB |
Flash |
64 MB |
Mean time between failures (MTBF) |
28.7 years when a 4-port 10GE interface card is configured, 41.1 years when a 2-port 10GE interface card is configured, 42.9 years when a 4-port GE interface card is configured |
Mean time to repair (MTTR) |
2 years |
Availability |
> 0.99999 |
Service port surge protection |
±2 kV in common mode |
Power supply surge protection |
|
Dimensions (H x W x D) |
44.4 mm x 442.0 mm x 220.0 mm (1.75 in. x 17.4 in. x 8.7 in.) |
Weight |
|
Stack ports |
|
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz -36 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
76.6 W |
Operating temperature |
-5°C to +55°C (23°F to 131°F) NOTE:
The operating temperature of the switch is -5°C to +50°C (23°F to 122°F) when it uses SFP+ optical modules with 40 km or longer transmission distances. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 60 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
|
Certification |
|
Part number |
02353630 |