S5700-28C-EI
Version Mapping
Table 4-707 lists the mapping between the S5700-28C-EI and software versions.
Appearance and Structure
1 |
Twenty-four 10/100/1000BASE-T ports |
2 |
One console port |
3 |
One ETH management port |
4 |
Front card slot |
5 |
ESD jack NOTE:
Before installing or maintaining a switch, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack. |
6 |
Rear card slot NOTE:
Card supported: |
7 |
Fan slot NOTE:
Applicable fan module: |
8 |
Power module slot 2 NOTE:
Applicable power modules:
|
9 |
Power module slot 1 NOTE:
Applicable power modules:
|
- |
- |
Port Description
10/100/1000BASE-T port
Console port
ETH management port
Indicator Description
No. |
Indicator/Button |
Color |
Description |
---|---|---|---|
1 |
PWR1: power module indicator |
- |
Off: No power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally. |
Green |
Steady on: A power module is installed in power module slot 1 and is working normally. |
||
Red |
Steady on: The switch has two power modules installed. Any of the following situations occurs in power module slot 1:
|
||
2 |
PWR2: power module indicator |
- |
Off: No power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally. |
Green |
Steady on: A power module is installed in power module slot 2 and is working normally. |
||
Red |
Steady on: The switch has two power modules installed. Any of the following situations occurs in power module slot 2:
|
||
3 |
SYS: system status indicator |
- |
Off: The system is not running. |
Green |
|
||
Yellow |
Steady on: The system is performing self-check during startup. |
||
Red |
Steady on: The system does not work normally after registration, or a fan alarm or temperature alarm has been generated. |
||
4 |
MODE: mode indicator |
- |
Off: The service port indicators are in the status mode (default). In the status mode, the service port indicator shows the port link or activity state. |
Green |
Steady on: The service port indicators show the port speed. After 45 seconds, the service port indicators automatically restore to the status mode. |
||
Red |
Steady on: The service port indicators show the stack ID of the switch. After 45 seconds, the service port indicators automatically restore to the status mode. |
||
5 |
Mode switch button |
- |
If you do not press the button within 45 seconds, the mode indicator restores to status mode. |
6 |
Service port indicator |
Meanings of service port indicators vary in different modes. For details, see Table 4-712. |
|
7 |
ETH indicator |
- |
Off: No link is established on the port. |
Green |
Steady on: The port is connected. |
||
Yellow |
Blinking: The port is sending or receiving data. |
Display Mode |
Color |
Status |
Description |
---|---|---|---|
Status |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|
Green |
Blinking |
The port is sending or receiving data. |
|
Speed |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
10M/100M/1000M port: The port is operating at 10/100 Mbit/s. 1000M/10GE port: The port is operating at 1000 Mbit/s. |
|
Green |
Blinking |
10M/100M/1000M port: The port is operating at 1000 Mbit/s. 1000M/10GE port: The port is operating at 10 Gbit/s. |
|
Stack |
- |
Off |
Port indicators do not show the stack ID of the switch. |
Green |
Steady on |
The switch is not the master switch in a stack.
|
|
Green |
Blinking |
The switch is the master switch in a stack.
|
Power Supply Configuration
The S5700-28C-EI can use a single power module or double power modules for 1+1 power redundancy. In versions prior to V200R005C00, the AC and DC power modules cannot be configured on the same device, while in V200R005C00 and later versions, they can be configured on the same device.
Heat Dissipation
The S5700-28C-EI uses pluggable fan modules for forced air cooling. Air flows in from the left and right sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-713 lists technical specifications of the S5700-28C-EI.
Item |
Description |
---|---|
Memory (RAM) |
256 MB |
Flash |
32 MB |
Mean time between failures (MTBF) |
53.11 years when a 2-port 10GE interface card is configured, 68.33 years when a 4-port GE front card is configured, 25.52 years when a 4-port 10GE front card is configured |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
±2 kV in common mode |
Power supply surge protection |
|
Dimensions (H x W x D) |
43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.) |
Weight |
|
Stack ports |
Two stack ports available on each stack card |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz -36 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
60 W |
Operating temperature |
0°C to 50°C (32°F to 122°F) |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 41 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
|
Certification |
|
Part number |
02352338 |