S5700-28P-LI-BAT
Version Mapping
Table 4-164 lists the mapping between the S5700-28P-LI-BAT chassis and software versions.
Appearance and Structure
1 |
Twenty-four 10/100/1000BASE-T ports |
2 |
Four 1000BASE-X ports |
3 |
One console port |
4 |
Ground screw NOTE:
It is used with a ground cable. |
5 |
AC socket NOTE:
It is used with an AC power cable. |
6 |
Jack for AC power cable locking strap NOTE:
The AC power cable locking strap is not delivered
with the switch. |
7 |
Battery slot |
- |
- |
Port Description
10/100/1000BASE-T port
1000BASE-X port
Console port
Indicator Description
- If the switch has no configuration file, the system attempts to enter the web initial login mode. In this mode, the status of mode indicators is as follows:
- If the system enters the web initial login mode successfully, all mode indicators turn green and stay on for a maximum of 10 minutes.
- If the system fails to enter the initial login mode, all mode indicators fast blink for 10 seconds and then restore to the default status.
- If the switch has a configuration file, the system cannot enter the web initial login mode. In this case, all mode indicators fast blink for 10s, and then return to the default states.
No. |
Indicator/Button |
Color |
Description |
---|---|---|---|
1 |
PWR: power supply indicator |
- |
Off: The switch is not powered on. |
Green |
Steady on: The switch is powered on. |
||
Yellow |
Steady on: The built-in power supply has failed, and the switch is powered by a backup power supply. |
||
2 |
BAT: battery indicator |
- |
Off:
|
Green |
|
||
Yellow |
Steady on:
Blinking: The lithium battery software is upgrading. (This indicator state is available in V200R005C00 and later versions.) |
||
3 |
SYS: system status indicator |
- |
Off: The system is not running. |
Green |
|
||
Red |
Steady on: The system is not running normally or has generated a temperature or fan alarm. |
||
4 |
STAT: status indicator |
Green |
|
5 |
SPED: speed indicator |
Green |
|
6 |
STCK: stack indicator |
- |
Off NOTE:
The S5700-LI-BAT series switches do not support the stacking feature. This indicator is reserved for future use. |
7 |
MODE: mode switch button |
- |
If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the STAT indicator is steady green, the SPED and STCK indicator are off. |
8 |
Service port indicator
|
Meanings of service port indicators vary in different modes. For details, see Table 4-169. |
Mode |
Color |
Description |
---|---|---|
Status mode |
Green |
|
Speed mode |
Green |
|
Power Supply Configuration
The S5700-28P-LI-BAT switch has a built-in AC power supply unit and can use a pluggable power module or battery for power redundancy. Power modules and batteries for the S5700-28P-LI-BAT switch are hot swappable.
Battery module configuration
The battery installed on an S5700-28P-LI-BAT switch can automatically supply power to the switch in case of a mains power outage, ensuring uninterrupted services. When the AC power supply recovers, the battery turns to the charging state.
- BAT-4AHA (chargeable lithium battery)
- BAT-8AHA (chargeable lithium battery)
- PBB-12AHA (12AH lead-acid battery charger module)
The PBB-12AHA module must connect to a lead-acid battery with 12AH of rated capacity.
The S5700-28P-LI-BAT switch can be configured with a battery to prevent service interruption caused by mains power outages. Table 4-170 lists the power supply time of the batteries.
Battery |
Power Supply Time |
---|---|
BAT-4AHA |
|
BAT-8AHA |
|
The power supply time shortens when a battery has been used for a long time.
Battery module configuration
The S5700-28P-LI-BAT switch can be configured with a power module as a backup of the built-in power supply unit to improve power reliability.
- 150 W AC power module
- 150 W DC power module
Heat Dissipation
The S5700-28P-LI-BAT has a built-in fan for forced air cooling. The airflow direction is left-to-right.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-171 lists technical specifications of the S5700-28P-LI-BAT.
Item |
Description |
---|---|
Memory (RAM) |
256 MB |
Flash |
200 MB |
Mean time between failures (MTBF) |
57.9 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±6 kV |
Power supply surge protection |
|
Dimensions (H x W x D) |
43.6 mm x 442.0 mm x 310.0 mm (1.72 in. x 17.4 in. x 12.2 in.) |
Weight (with packaging) |
3.4 kg (7.5 lb) |
Stack ports |
Not supported |
RTC |
Not supported |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz -36 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
23 W |
Typical power consumption (30% of traffic load)
|
22.7 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage temperature |
|
Noise under normal temperature (27°C, sound power) |
< 43.2 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
|
Certification |
|
Part number |
98010509 |