S5735-S8P2X-IA200H1
Overview
Item | Details |
---|---|
Description | Function Module, S5735-S8P2X-IA200H1, Single-Phase Or Dual-Live Wire Or PV Input, PoE 53Vdc/3.8A, 12Vdc/6A, 24Vac/4A, Natural Heat Dissipation |
Part Number | 02313CMQ |
Model | S5735-S8P2X-IA200H1 |
First supported version | V200R020C10 |
Remarks | External power supply capability: When only AC input is used: Maximum output power: 300 W (AC input range: 100 V AC to 120 V AC) Maximum output power: 450 W (AC input range: 200 V AC to 240 V AC) When only PV input is used: Maximum output power: 500 W (DC input range: 36 V DC to 58 V DC) Maximum output power: 1400 W (DC input range: 58 V DC to 72 V DC) Maximum output power: 1000 W (DC input range: 72 V DC to 120 V DC) When PV and AC power inputs are included: Maximum output power: 1400 W When lithium batteries are used, the lithium battery charging capability is the maximum output power minus the power consumption (including 12 V DC, 24 V AC, PoE, and device power consumption). |
Components
1 |
Eight 10/100/1000BASE-T PoE+ ports |
2 |
One USB port |
3 |
Two 10GE SFP+ ports |
4 |
One ETH management port |
5 |
One console port |
6 |
DI/DO monitoring port
NOTE:
The monitoring port can be used to detect the status of a connected external device, such as the opening and closing of the maintenance compartment door. The monitoring port is used with a conductive cable. The minimum cross-sectional area of the conductor connected to a conductive cable is 0.3 mm2 or 22 AWG, and the maximum cross-sectional area of the conductor is 1.3 mm2 or 16 AWG. For details about how to use a monitoring port, see "Monitoring Interface Configuration" in the Configuration Guide - Device Management Configuration. |
7 |
FE communication port NOTE:
The FE communication port is used for power commissioning.
|
8 |
Monitoring port (reserved) |
9 |
Temperature sensor port (reserved) |
10 |
COM1 and COM2 ports (reserved) |
11 |
RS485 port NOTE:
The RS485 port is used to communicate with a PC for commissioning the power locally.
|
12 |
Cable outlet |
13 |
COM_CAN port NOTE:
This port can be connected to lithium batteries to monitor and manage the batteries.
|
14 |
Photovoltaics (PV) input port NOTE:
This port can be connected to an external PV system to supply power to the switch. |
15 |
BAT port NOTE:
This port can be connected to an external lithium battery to supply power to the switch or charge the lithium battery. |
16 |
220 V AC power input socket |
17 |
Cable outlet |
18 |
Ground screw NOTE:
It is used to ground the switch. |
19 |
24 V AC power output socket NOTE:
The switch provides two 24 V AC outputs to external devices, such as strobe lights and non-PoE PTZ dome cameras. |
20 |
12 V DC power output socket NOTE:
The switch provides two 12 V DC outputs to external devices, such as strobe lights and non-PoE PTZ dome cameras. |
21 |
220 V AC power output circuit breaker NOTICE:
One 220 V AC power output is provided. The 220 V AC power output circuit breaker provides only overcurrent protection. The connected external devices need to provide certain surge protection capabilities. It is recommended that the surge protection capabilities for both differential and common modes be 20 kA. |
22 |
Fiber management tray (FMT) |
23 |
Door status sensor NOTE:
It reports an alarm when the maintenance compartment door of the switch is opened. |
- |
- |
Indicators Description
No. |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
PWR |
Power indicator |
- |
Steady off |
The switch is powered off. |
Green |
Steady on |
The switch is powered on and can communicate with the built-in power module properly. |
|||
Yellow |
Steady on |
The switch is powered on but cannot communicate with the built-in power module properly. |
|||
2 |
SYS |
System status indicator |
- |
Steady off |
The system is not running. |
Green |
Fast blinking |
The system is starting. |
|||
Green |
Steady on |
In the system startup preparation phase, the SYS indicator is steady green for no more than 30 seconds. |
|||
Green |
Slow blinking |
The system is running normally. |
|||
Red |
Steady on |
The system does not work normally after registration, or a temperature alarm has been generated. |
|||
Red |
Fast blinking |
The indicator identifies the switch to maintain. The indicator can be turned on or off remotely to help field engineers find the switch to maintain. |
|||
3 |
ALM |
Alarm indicator |
- |
Steady off |
There is no protection alarm or fault alarm. |
Red |
Steady on |
A fault alarm is generated due to device faults and cannot be cleared. |
|||
Red |
Slow blinking |
A protection alarm is generated due to external faults and can be cleared. |
|||
4 |
USB |
USB-based deployment indicator |
- |
Steady off |
|
Green |
Steady on |
A USB-based deployment has been completed. |
|||
Green |
Blinking |
The system is reading data from a USB flash drive. |
|||
Yellow |
Steady on |
The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch. |
|||
Red |
Blinking |
An error has occurred when the system is executing the configuration file or reading data from the USB flash drive. |
|||
5 |
- |
Service port indicator |
Green |
Steady off |
The port is not connected or has been shut down. |
Steady on |
The port is connected. |
||||
Blinking |
The port is sending or receiving data. |
||||
Yellow |
Steady off |
The port does not supply power to any PD. |
|||
Steady on |
The port is supplying power to the connected PD. |
||||
Blinking |
The PD connected to the port is not a standard PD or its power exceeds the maximum power or power threshold of the port. |
||||
6 |
- |
ETH port indicator |
- |
Steady off |
The ETH port is not connected. |
Green and yellow |
Steady on |
The ETH port is connected. |
|||
Green and yellow |
Blinking |
The port is sending or receiving data. |
Ports
Port | Connector Type | Description | Available Components |
---|---|---|---|
10/100/1000BASE-T PoE+ port | RJ45 | A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s. The port supports the PoE function. |
|
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. If one port uses a GPON optical module, the other port cannot be used at the same time. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. |
|
USB port | USB 2.0 Type A | The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives. |
USB flash drive |
Power Supply System
The S5735-S8P2X-IA200H1 has a built-in AC power module and can be directly connected to the AC mains or an external PV system. External lithium batteries can also be connected to the switch for power backup. The switch supports the following power supply combinations:
- Solar hybrid scenario: PV input, AC mains input, and lithium batteries for backup
- Grid hybrid scenario: AC mains input and lithium batteries for backup
- Mains scenario: AC mains input
- Solar-Only scenario: PV input and lithium batteries for backup
Item |
Description |
---|---|
Function module |
S5735-S8P2X-IA200H1 |
Lithium battery |
Maximum configuration: two DBU20B-N12A3s or two DBU50B-N12A1s |
Pole |
Solar pole |
PV module |
Two PV modules |
Item |
Description |
---|---|
Function module |
S5735-S8P2X-IA200H1 |
Lithium battery |
Maximum configuration: two DBU20B-N12A3s or two DBU50B-N12A1s |
Pole |
Mains pole |
Item |
Description |
---|---|
Function module |
S5735-S8P2X-IA200H1 |
Pole |
Mains pole |
Item |
Description |
---|---|
Function module |
S5735-S8P2X-IA200H1 |
Lithium battery |
Maximum configuration: two ESM-48100Bs or two ESM-48100A8s |
Pole |
Solar pole |
PV module |
Two PV modules or Four PV modules |
For details about poles, lithium batteries, and PV modules, see PowerCube 500 User Manual (S5735-S8P2X-IA200H1).
The S5735-S8P2X-IA200H1 can also supply power to external devices. For details, see Table 4-1946.
Power Supply Mode |
Available Power |
---|---|
PoE |
200 W Maximum number of PoE ports (fully loaded):
|
12 V DC |
Two 12 V DC outputs provide a total of 72 W power. The maximum power of a single output is 72 W. |
24 V AC |
Two 24 V AC outputs provide a total of 100 W power. The maximum power of a single output is 100 W. |
The total maximum output power of PoE power output, two 12 V DC outputs, and two 24 V AC outputs is 200 W.
In the following scenarios, a device can supply up to 190 W available power.
- PoE-only scenario: If a device that is supplying more than 190 W PoE power is restarted upon power-off or is reset, the device can only supply up to 190 W available power due to load fluctuation errors.
- Hybrid power supply scenario: When a device uses both PoE and 12 V/24 V power supplies, and the device is powered on with loads, is restarted upon power-off, or is reset, the device can only supply up to 190 W power due to load fluctuation errors.
Heat Dissipation System
The S5735-S8P2X-IA200H1 has no fans and uses natural heat dissipation.
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Including the protruding portions: 582 mm x 300 mm x 165.5 mm (22.91 in. x 11.81 in. x 6.52 in.) Excluding the protruding portions: 570 mm x 300 mm x 150 mm (22.44 in. x 11.81 in. x 5.91 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 270 mm x 450 mm x 670 mm (10.63 in. x 17.72 in. x 26.38 in.) |
Weight without packaging [kg(lb)] | 14.5 kg (31.97 lb) |
Weight with packaging [kg(lb)] | 17.6 kg (38.8 lb) |
Typical power consumption [W] | 38 W |
Typical heat dissipation [BTU/hour] | 129.66 BTU/hour |
Maximum power consumption [W] |
|
Maximum heat dissipation [BTU/hour] |
|
Static power consumption [W] | 37 W |
MTBF [year] | 41.85 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | Noise-free (no fans) |
Noise at normal temperature (acoustic pressure) [dB(A)] | Noise-free (no fans) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 0 |
Redundant power supply | The S5735-S8P2X-IA200H1 has a built-in AC power module and can be directly connected to the AC mains or an external PV system. External lithium batteries can also be connected to the switch for power backup. |
Long-term operating temperature [°C(°F)] | -40°C to +55°C (-40°F to 131°F) NOTE:
–35ºC to +55ºC (–31ºF to +131ºF): sunshade needed; no requirement on the air velocity; GPON optical modules supported –35ºC to +45ºC (–31ºF to +113ºF): 1120 W/m2 solar radiation (maximum); no requirement on the air velocity –40ºC to –35ºC (–40ºF to –31ºF): Stable port performance can be achieved only when at least four Ethernet electrical ports go Up. |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 2000-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 200 m (656 ft.). |
Storage temperature [°C(°F)] | -40°C to +85°C (-40°F to +185°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | -150 m to 5000 m (-492 to 16404 ft.) |
Storage altitude [m(ft.)] | -150 m to 5000 m (-492 to 16404 ft.) |
Power supply mode |
|
Rated input voltage [V] | AC input: 100 V AC to 240 V AC, 50/60 Hz PV input: 72 V DC Battery input: 53.5 V DC |
Input voltage range [V] | AC input: 85 V AC to 290 V AC, 45 Hz to 65 Hz PV input: 36 V DC to 120 V DC |
Maximum input current [A] | AC input: 4.5 A PV input: 28 A |
Memory | 1 GB |
Flash memory | 512 MB in total. To view the available flash memory size, run the display version command. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Not supported |
RPS input | Not supported |
Service port surge protection [kV] | ±1.5 kV in differential mode, ±6 kV in common mode |
Power supply surge protection [kV] | Surge current:
Surge:
|
Types of fans | None |
Heat dissipation mode | Natural heat dissipation without fans |
Airflow direction | - |
PoE | Supported |
Certification | EMC certification Safety certification Manufacturing certification |
The protection level of the device is IP55 and can be installed in a class C environment (GR-487).