Huawei utilizza la traduzione automatica insieme alla revisione umana per tradurre questo documento in diverse lingue, per facilitare la comprensione del contenuto di questo documento. Nota: la traduzione automatica, anche la più avanzata, non può corrispondere alla qualità dei trasduttori professionisti. Huawei non accetta alcuna responsabilità per l'accuratezza della traduzione e raccomanda di fare riferimento al documento inglese (per il quale è stato fornito un collegamento).
Configuring Association Between BFD and a Card

Configuring Association Between BFD and a Card

Context

After VRRP is enabled on a switch used as the aggregation device and gateway, VRRP Advertisement packets are forwarded through a Layer 2 switch at the access layer. To improve the VRRP switching performance, associate VRRP with BFD. In this case, BFD packets are also forwarded through a Layer 2 switch at the access layer.

If uplink outbound interfaces of a VRRP group are located on the same card, the card reset may cause a failure to forward user traffic because there is no outbound interface. In this situation, a VRRP active/standby switchover must be performed. The link monitored by BFD is normal and the BFD session does not go Down, so the millisecond-level switching performance cannot be ensured. After a BFD session is associated with a card and the card is set, the BFD session immediately goes Down, triggering the VRRP active/standby switchover. The switching performance is therefore improved.

NOTE:

The S7706 and S7712 support this command only when the MPU is equipped with the ES0D00FSUA00.

The S9706 and S9712 support this command only when the MPU is EH1D2SRUDC00/EH1D2SRUDC01.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run bfd-track slot slot-id [ interval second-time ]

    BFD is associated with a card.

    By default, BFD is not associated with a card.