Configuration Guide - Reliability

S7700 and S9700 V200R011C10

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback:
Huawei utilizza la traduzione automatica insieme alla revisione umana per tradurre questo documento in diverse lingue, per facilitare la comprensione del contenuto di questo documento. Nota: la traduzione automatica, anche la più avanzata, non può corrispondere alla qualità dei trasduttori professionisti. Huawei non accetta alcuna responsabilità per l'accuratezza della traduzione e raccomanda di fare riferimento al documento inglese (per il quale è stato fornito un collegamento).
Configuring Association Between a BFD Session and an Interface to Trigger the Associated Interface in Down State

Configuring Association Between a BFD Session and an Interface to Trigger the Associated Interface in Down State

Pre-configuration Tasks

Before configuring association between a BFD session and an interface, create a BFD session.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run oam-mgr

    The OAM management view is displayed.

  3. Run the following commands as required.

    • Run oam-bind ingress bfd-session bfd-session-id trigger if-down egress interface interface-type interface-number

      A BFD session is configured to report faults to an interface.

      By default, a BFD session is not enabled to report faults to an interface.

      When a BFD session detects a fault, the physical status of the interface bound to the BFD session becomes Down.

    • Run oam-bind ingress interface interface-type interface-number egress bfd-session bfd-session-id trigger if-down

      An interface is configured to report faults to a BFD session.

      By default, an interface is not enabled to report faults to a BFD session.

      When an interface becomes Down, the OAM management module sends a fault notification message to the BFD session bound to the interface. Then the fault notification message is sent to the remote device through the BFD session.

    • Run oam-bind bfd-session bfd-session-id trigger if-down interface interface-type interface-number

      The BFD session and the interface are configured to report faults to each other.

      By default, a BFD session and an interface are not enabled to report faults to each other.

      NOTE:

      If the oam-bind bfd-session bfd-session-id trigger if-down interface interface-type interface-number command is run, the oam-bind ingress bfd-session bfd-session-id trigger if-down egress interface interface-type interface-number and oam-bind ingress interface interface-type interface-number egress bfd-session bfd-session-id trigger if-down commands will be displayed in the configuration file.

      The physical interface associated with BFD cannot be the interface of the BFD link. Otherwise, a link deadlock occurs.