Nessuna risorsa pertinente trovata nella lingua selezionata.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Reliability

S7700 and S9700 V200R011C10

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback:
Huawei utilizza la traduzione automatica insieme alla revisione umana per tradurre questo documento in diverse lingue, per facilitare la comprensione del contenuto di questo documento. Nota: la traduzione automatica, anche la più avanzata, non può corrispondere alla qualità dei trasduttori professionisti. Huawei non accetta alcuna responsabilità per l'accuratezza della traduzione e raccomanda di fare riferimento al documento inglese (per il quale è stato fornito un collegamento).
Configuring Association Between EFM and EFM

Configuring Association Between EFM and EFM

Context

For details on the principle and usage scenarios of association between EFM and EFM, see Fault Information Advertisement Between EFM and Other Modules.

Association between EFM and EFM is bidirectional.

You must perform operations on both EFM-enabled devices of a link.

Pre-configuration Tasks

Before configuring association between EFM and EFM, perform the task of Configuring Basic EFM Functions.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run oam-mgr

    The OAM management view is displayed.

  3. Run the following commands as required.

    • Unidirectional association

      Run the oam-bind ingress efm interface interface-type interface-number egress efm interface interface-type interface-number command to configure EFM on one link to notify EFM on the other link of faults.

    • Bidirectional association

      Run the oam-bind efm interface interface-type interface-number efm interface interface-type interface-number command to configure EFM on two links to notify each other of faults.

    NOTE:

    The functions of two commands used to configure association functions in opposite directions are the same as those of the command used to configure the bidirectional association function.

    If the oam-bind efm interface interface-type interface-number efm interface interface-type interface-number command is run, two oam-bind ingress efm interface interface-type interface-number egress efm interface interface-type interface-number commands used to configure association functions in opposite directions will be displayed in the configuration file.

Traduzione
Download
Updated: 2019-09-23

N. documento: EDOC1000178318

Visualizzazioni:124347

Download: 81

Average rating:
This Document Applies to these Products
Documenti correlati
Related Version
Share
Precedente Avanti