Configuration Guide - Reliability

S7700 and S9700 V200R011C10

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback:
Huawei utilizza la traduzione automatica insieme alla revisione umana per tradurre questo documento in diverse lingue, per facilitare la comprensione del contenuto di questo documento. Nota: la traduzione automatica, anche la più avanzata, non può corrispondere alla qualità dei trasduttori professionisti. Huawei non accetta alcuna responsabilità per l'accuratezza della traduzione e raccomanda di fare riferimento al documento inglese (per il quale è stato fornito un collegamento).
Configuring Association Between CFM Modules

Configuring Association Between CFM Modules

Context

For details on the principle and usage scenarios of association between CFM modules, see Fault Information Advertisement Between CFM and Other Modules.

Association between CFM modules is bidirectional. CFM modules notify each other of faults.

You must perform operations on both CFM-enabled devices of a link.

Pre-configuration Tasks

Before configuring association between CFM modules, perform the task of Configuring Basic Ethernet CFM Functions.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run oam-mgr

    The OAM management view is displayed.

  3. Configure unidirectional or bidirectional transmission of fault information between CFM modules. Choose a configuration solution according to usage scenarios.

    Faults need to be transmitted bidirectionally between CFM modules.

    • Configuration Solution 1

      Run the oam-bind cfm md ma cfm md ma command to configure CFM modules to report faults to each other.
      NOTE:

      If the oam-bind cfm md ma cfm md ma command is used, two commands of oam-bind ingress cfm md ma egress cfm md ma in opposite directions will be displayed in the configuration file.

    • Configuration Solution 2

      Use the following commands:
      • Run the oam-bind ingress cfm md ma egress cfm md ma command to configure CFM for the link at one side of the device to report faults to CFM for the link at the other side of the device. ingress md md-name1 and ma ma-name1 specify the MD name and MA name of a link at one side of the device respectively. egress md md-name2 and ma ma-name2 specify the MD name and MA name of a link at the other side of the device respectively.

      • Run the oam-bind ingress cfm md ma egress cfm md ma command to configure CFM for the link at one side of the device to report faults to CFM for the link at the other side of the device. ingress md md-name1 and ma ma-name1 specify the MD name and MA name of a link at one side of the device respectively. egress md md-name2 and ma ma-name2 specify the MD name and MA name of a link at the other side of the device respectively.

    Faults need to be transmitted unidirectionally between CFM modules.

    Choose either of the following commands based on the transmission direction:

    • Run the oam-bind ingress cfm md ma egress cfm md ma command to configure CFM for the link at one side of the device to report faults to CFM for the link at the other side of the device. ingress md md-name1 and ma ma-name1 specify the MD name and MA name of a link at one side of the device respectively. egress md md-name2 and ma ma-name2 specify the MD name and MA name of a link at the other side of the device respectively.

    • Run the oam-bind ingress cfm md ma egress cfm md ma command to configure CFM for the link at one side of the device to report faults to CFM for the link at the other side of the device. ingress md md-name1 and ma ma-name1 specify the MD name and MA name of a link at one side of the device respectively. egress md md-name2 and ma ma-name2 specify the MD name and MA name of a link at the other side of the device respectively.