Configuration Guide - Reliability

S7700 and S9700 V200R011C10

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback:
Huawei utilizza la traduzione automatica insieme alla revisione umana per tradurre questo documento in diverse lingue, per facilitare la comprensione del contenuto di questo documento. Nota: la traduzione automatica, anche la più avanzata, non può corrispondere alla qualità dei trasduttori professionisti. Huawei non accetta alcuna responsabilità per l'accuratezza della traduzione e raccomanda di fare riferimento al documento inglese (per il quale è stato fornito un collegamento).
Configuring 802.1ag MAC Ping

Configuring 802.1ag MAC Ping

Context

Similar to IP ping, 802.1ag MAC ping monitors connectivity of a path between a MEP and an RMEP.

802.1ag MAC ping can be only implemented on the network where the MD, MA, and MEP are configured.

Procedure

  1. A device is usually configured with multiple MDs and MAs. To accurately detect connectivity of a link between two or more devices, perform either of the following operations.

    • MA view:

      1. Run system-view

        The system view is displayed.

      2. Run cfm md md-name

        The MD view is displayed.

      3. Run ma ma-name

        The MA view is displayed.

      4. Run ping mac-8021ag mep mep-id mep-id { md md-name ma ma-name { mac mac-address | remote-mep mep-id mep-id } | mac mac-address | remote-mep mep-id mep-id } [ -c count | interface interface-type interface-number | -s packetsize | -t timeout | -p priority-value ] *

        Connectivity between a MEP and an RMEP or a MIP is monitored.

      • The ping mac-8021ag command without md md-name and ma ma-name specified checks connectivity of links in a specified MA.

      • The ping mac-8021ag command with md md-name and ma ma-name specified checks connectivity of links based on the configured MA and MD.

    • All views except the MA view:

      Run ping mac-8021ag mep mep-id mep-id md md-name ma ma-name { mac mac-address | remote-mep mep-id mep-id } [ -c count | interface interface-type interface-number | -s packetsize | -t timeout | -p priority-value ] *

      Connectivity between a MEP and an RMEP or a MIP is monitored.

    When performing 802.1ag MAC ping, ensure that:

    • The MA has been associated with a VLAN.

    • The MEP has been configured in the MA.

    • The outbound interface (if specified) cannot be the interface on which an inward-facing MEP is configured. The interface must join the VLAN associated with the MA.

    • If the destination node is an RMEP, either mac mac-address or remote-mep mep-id mep-id can be specified. If remote-mep mep-id mep-id is specified, the RMEP must have been created using the remote-mep command and the bridge MAC address of the device on which the RMEP is located must be specified.

    • If the destination node is a MIP, specify mac mac-address.

    An intermediate device on a link is only used to forward LBMs and LBR messages; therefore, the intermediate device does not need to be configured with the MD, MA, or MEP.