常见RAID卡启动消息
表A-5描述了MegaRAID固件中出现的启动错误消息。
序号 |
显示的启动消息 |
原因及处理方法/建议 |
---|---|---|
1 |
Memory or battery problems were detected. The adapter has recovered, but cached data was lost. Press any key to continue, or press C to load the configuration utility. |
原因:缓存数据丢失,无法检索。 处理方法:进行内存和电池测试。如果需要,更换电池或RAID卡。 |
2 |
This is a test message. You can press a key to ignore it, or you can wait five seconds. No further action is required. Press any key to continue, or press C to load the configuration utility. |
这是一条测试消息,可以按任意键忽略,或者等待五秒,无需进一步处理。 |
3 |
Firmware version inconsistency was detected. The adapter has recovered, but cached data was lost. Press any key to continue, or press C to load the configuration utility. |
原因:检测到固件版本不一致。适配器已恢复,但是缓存的数据已经丢失。 处理方法:确保另一个控制器也具有相同的固件版本。 |
4 |
Foreign configuration(s) found on adapter. Press any key to continue or press C to load the configuration utility or press F to import foreign configuration(s) and continue. |
原因:插入了一个存储设备,其中的元数据不属于控制器识别的任何RAID组。 处理方法:导入已插入的存储设备的配置或删除RAID组。 |
5 |
Previous configuration cleared or missing. Importing configuration created on %02d/%02d%2d:%02d. Press any key to continue, or press C to load the configuration utility. |
原因:控制器无法识别当前RAID组配置。 处理方法:导入配置或删除存储设备上的外部配置。 |
6 |
Firmware package: %s |
无 |
7 |
Firmware version: %s |
无 |
8 |
This firmware is a TEST version. It has not completed any validation. |
原因:控制器无法识别当前RAID组配置。 处理方法:将固件升级到正确的版本。 |
9 |
This firmware is an ALPHA version – It has not completed all validation. The validation stamp is: %s""" |
原因:控制器无法识别当前RAID组配置。 处理方法:将固件升级到正确的版本。 |
10 |
This firmware is BETA version – It has not completed all validation. The validation stamp is: %s""" |
原因:控制器无法识别当前RAID组配置。 处理方法:将固件升级到正确的版本。 |
11 |
An enclosure was found that contains both SAS and SATA drives, but this controller does not allow mixed drive types in a single enclosure. Correct the problem then restart your system. Press any key to continue, or press C to load the configuration utility. |
原因:不能使用同时包含SAS和SATA盘的Enclosure,因为控制器不支持包含混合磁盘类型的Enclosure。 处理方法:
|
12 |
SAS drives were detected, but this controller does not support SAS drives. Remove the SAS drives then restart your system. Press any key to continue, or press C to load the configuration utility. |
原因:该控制器不支持SAS盘。 处理方法:更换SAS盘为SATA盘并重启系统。 |
13 |
SATA drives were detected, but this controller does not support SATA drives. Remove the SATA drives then restart your system. Press any key to continue, or press C to load the configuration utility. |
原因:该控制器不支持SATA盘。 处理方法:将SATA盘替换为SAS盘并重启系统。 |
14 |
There are %d enclosures connected to connector %s, but only maximum of %d enclosures can be connected to a single SAS connector. Remove the extra enclosures then restart your system. |
原因:该控制器只支持特定数量的Enclosure。 处理方法:移除多余的Enclosure或插入满足需求的控制器。 |
15 |
Invalid SAS topology detected. Check your cable configurations, repair the problem, and restart your system. |
原因:控制器检测到无效的SAS拓扑。 处理方法:检查线缆或重新配置连接的设备以创建有效的SAS拓扑。 |
16 |
The battery is currently discharged or disconnected. Verify the connection and allow 30 minutes for charging. If the battery is properly connected and it has not returned to operational state after 30 minutes of charging then contact technical support for additional assistance. |
原因:电池当前处于放电或断开状态。 处理方法:
|
17 |
The battery hardware is missing or malfunctioning, or the battery is unconnected, or the battery could be fully discharged. If you continue to boot the system, the battery-backed cache will not function. If battery is connected and has been allowed to charge for 30 minutes and this message continues to appear, contact technical support for assistance. Press D to disable this warning (if your controller does not have a battery) |
原因:电池硬件缺失或故障,或电池未连接,或电池完全放电。 处理方法:
|
18 |
Invalid SAS Address present in MFC data. Program a valid SAS Address and restart your system. |
原因:可能存在无效的SAS地址。 处理方法:
|
19 |
Some configured disks have been removed from your system, or are no longer accessible. Check your cables and also make sure all disks are present. Press any key to continue, or press C to load the configuration utility. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
20 |
The following VDs have missing disks: %s. If you proceed (or load the configuration utility), these VDs will be marked OFFLINE and will be inaccessible. Check your cables and make sure all disks are present. Press any key to continue, or press C to load the configuration utility. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
21 |
The following VDs are missing: %s. If you proceed (or load the configuration utility), these VDs will be removed from your configuration. If you wish to use them at a later time, they will have to be imported. If you believe these VDs should be present, power off your system and check your cables to make sure all disks are present. Press any key to continue, or press C to load the configuration utility. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
22 |
The following VDs are missing complete spans: %s. If you proceed (or load the configuration utility), these VDs will be removed from your configuration and the remaining drives marked as foreign. If you wish to use them at a later time, restore the missing span(s) and use a foreign import to recover the VDs. If you believe these VDs should be present, please power off your system and check your cables to make sure all disks are present. Press any key to continue, or press C to load the configuration utility. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
23 |
All of the disks from your previous configuration are gone. If this is an unexpected message, power off your system and check your cables to make sure all disks are present. Press any key to continue, or press C to load the configuration utility. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
24 |
The cache contains dirty data, but some VDs are missing or will go offline, so the cached data can not be written to disk. If this is an unexpected error, power off your system and check your cables to make sure all disks are present. If you continue, the data in cache will be permanently discarded. Press X to acknowledge and permanently destroy the cached data. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
25 |
Your VDs that are configured for Write-Back are temporarily running in Write-Through mode. This is caused by the battery being charged, missing, or bad. Allow the battery to charge for 24 hours before evaluating the battery for replacement. The following VDs are affected: %s Press any key to continue. |
原因:配置为Write Back策略的虚拟磁盘暂时以Write Through方式运行。因为电池正在充电,或者电池已经丢失、损坏。 处理方法:
|
26 |
Invalid memory configuration detected. Contact your system support. System has halted. |
原因:检测到无效内存配置。 处理方法:更换RAID卡。 |
27 |
Cache data was lost due to an unexpected power-off or reboot during a write operation, but the adapter has recovered. This could be because of memory problems, bad battery, or you might not have a battery installed. Press any key to continue or C to load the configuration utility. |
原因:在写操作过程中,可能因为内存问题、电池损坏、或者未安装电池等原因,造成意外断电或重启,导致缓存数据丢失,但适配器已恢复。 处理方法:
|
28 |
Entering the configuration utility in this state will result in drive configuration changes. Press Y to continue loading the configuration utility or power off your system and check your cables to make sure all disks are present and reboot the system. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
29 |
Multibit ECC errors were detected on the RAID controller. If you continue, data corruption can occur. Contact technical support to resolve this issue. Press X to continue, otherwise power off the system, replace the controller, and reboot. |
原因:在RAID控制器上检测到Multibit(多比特)ECC错误。如果继续,可能会导致数据损坏。 处理方法:
|
30 |
Single-bit ECC errors were detected on the RAID controller. Contact technical support to resolve this issue. Press X to continue or else power off the system, replace the controller, and reboot. |
原因:在RAID控制器上检测到单比特(Single-bit)ECC错误。 处理方法:
|
31 |
Single-bit overflow ECC errors were detected on the RAID controller. If you continue, data corruption can occur. Contact technical support to resolve this issue. Press X to continue or else power off the system, replace the controller, and reboot. |
原因:RAID控制器上检测到单比特(Single-bit)溢出ECC错误。如果继续,可能会导致数据损坏。 处理方法:
|
32 |
Multibit ECC errors were detected on the RAID controller. The DIMM on the controller needs replacement. Contact technical support to resolve this issue. If you continue, data corruption can occur. Press X to continue, otherwise power off the system and replace the DIMM module and reboot. If you have replaced the DIMM press X to continue. |
原因:在RAID控制器上检测到Multibit(多比特)ECC错误。 处理方法:
|
33 |
Single-bit ECC errors were detected during the previous boot of the RAID controller. The DIMM on the controller needs replacement. Contact technical support to resolve this issue. Press X to continue, otherwise power off the system and replace the DIMM module and reboot. If you have replaced the DIMM press X to continue. |
原因:RAID控制器在上一次启动过程中检测到单比特(Single-bit)ECC错误。 处理方法:
|
34 |
Single-bit overflow ECC errors were detected during the previous boot of the RAID controller. The DIMM on the controller needs replacement. Contact technical support to resolve this issue. If you continue, data corruption can occur. Press X to continue, otherwise power off the system and replace the DIMM module and reboot. If you have replaced the DIMM press X to continue. |
原因:RAID控制器在上一次启动过程中检测到单比特(Single-bit)溢出ECC错误。 处理方法:
|
35 |
The attached enclosure does not support in controller's Direct mapping mode. Contact your system support. The system has halted because of an unsupported configuration. |
原因:可能存在过多串联的Enclosure,也可能与磁盘中的安全特性有关。 处理方法:
|
36 |
Expander detected in controller with direct mapping mode. Reconfiguring automatically to persistent mapping mode. Automatic reboot would happen in 10 seconds. |
原因:在直接映射模式下,控制器检测到了Expander。 处理方法:无需处理。控制器将自身配置为持久映射模式然后重新启动。 如果问题仍然存在,联系技术支持。 |
37 |
Your controller's I/O processor has a fault that can potentially cause data corruption. Your controller needs replacement. Contact your system support. To continue, press Y to acknowledge. |
原因:控制器的I/O处理器有一个可能导致数据损坏的故障。 处理方法:联系技术支持更换控制器。 |
38 |
The number of disks exceeded the maximum supported count of %d disks. Remove the extra drives and reboot system to avoid losing data. Press Y to continue with extra drives. |
原因:磁盘数量超过上限。 处理方法:
|
39 |
The number of devices exceeded the maximum limit of devices per quad. Remove the extra drives and reboot the system to avoid losing data. System has halted due to unsupported configuration. |
原因:磁盘数量超过上限。 处理方法:
|
40 |
A discovery error has occurred, power cycle the system and all the enclosures attached to this system. |
原因:发生了Discovery错误,对系统及所有与系统连接的Enclosure进行上下电。 处理方法:
|
41 |
Drive security is enabled on this controller and a pass phrase is required. Enter the pass phrase. |
原因:控制器上启用了磁盘安全特性,需要输入密码。 处理方法:输入密码。 |
42 |
Invalid pass phrase. Enter the pass phrase. |
原因:无效的密码。 处理方法:输入有效的密码。 |
43 |
There was a drive security key error. All secure drives will be marked as foreign. Press any key to continue, or C to load the configuration utility. |
原因:磁盘安全key错误,所有安全磁盘将被标记为Foreign。 处理方法:检查控制器是否支持自加密磁盘。 |
44 |
Invalid pass phrase. If you continue, a drive security key error will occur and all secure configurations will be marked as foreign. Reboot the machine to retry the pass phrase or press any key to continue. |
原因:无效的密码。 处理方法:重启系统重试密码或按任意键继续。 |
45 |
Unable to communicate to EKMS. If you continue, there will be a drive security key error and all secure configurations will be marked as foreign. Check the connection with the EKMS, reboot the machine to retry the EKMS or press any key to continue. |
原因:无法与EKMS通信。 处理方法:检查与EKMS的连接,重启系统,重新建立与EKMS的连接。 |
46 |
Unable to change security to EKMS as not able to communicate to EKMS. If you continue, the drive security will remain to existing security mode. Check the connection with the EKMS, reboot the machine to retry the EKMS or press any key to continue. |
原因:无法与EKMS通信,无法将安全模式修改为EKMS。 处理方法:检查与EKMS的连接,重启系统,重新建立与EKMS的连接。 |
47 |
DKM existing key request failed; existing secure configurations will be labeled foreign and will not be accessible. Reboot the server to retry. |
原因:DKM现有key请求失败;现有的安全配置将被标记为“Foreign”且不能访问。 处理方法:检查与EKMS的连接,重启系统,重新建立与EKMS的连接。 |
48 |
DKM new key request failed; controller security mode transition was not successful. Reboot the server to retry request, or press any key to continue. |
原因:DKM新key请求失败;控制器安全模式转换不成功。 处理方法:检查与EKMS的连接,重启系统,重新建立与EKMS的连接。 |
49 |
Firmware did not find valid NVDATA image. Program a valid NVDATA image and restart your system. Press any key to continue. |
原因:固件没有找到有效的NVDATA镜像。 处理方法:
|
50 |
IR to MR Migration failed. Press any key to continue with MR defined NVDATA values |
原因:IR到MR迁移失败,按任意键继续使用MR定义的NVDATA值。 处理方法:无 |
51 |
Two BBUs are connected to the adapter. This is not a supported configuration. Battery and caching operations are disabled. Remove one BBU and reboot to restore battery and caching operations. If dirty cache is lost in this boot, that could have been because of dual battery presence. |
原因:适配器连接着两个BBU,由于不支持这种配置,电池和缓存操作已被禁用。 处理方法:移除一个BBU,重启系统,恢复电池和缓存操作。 由于存在双电池,在系统重启过程中,可能会丢失脏缓存中的数据。 |
52 |
Offline or missing virtual drives with preserved cache exist. Check the cables and make sure that all drives are present. Press any key to continue, or C to load the configuration utility. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
53 |
Offline or missing virtual drives with preserved cache exist. Check the cables and make sure that all drives are present. Press any key to enter the configuration utility. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
54 |
Invalid SAS Address present in SBR. Contact your system support. Press any key to continue with Default SAS Address. |
原因:SBR中存在无效的SAS地址。 处理方法:联系技术支持恢复出厂配置默认值。 |
55 |
Incompatible secondary iButton present! Insert the correct iButton and restart the system. Press any key to continue but OEM specific features will not be upgraded! |
原因:存在不兼容的RAID key。 处理方法:插入正确RAID key,重启系统。如果问题仍然存在,联系技术支持更换RAID key。 |
56 |
Upgrade Key Missing! An upgrade key was present on a previous power cycle, but it is not connected. This can result in inaccessible data unless it is addressed. Re-attach the upgrade key and reboot. |
原因:前一个上下电周期中存在的升级key可能无法连接。 处理方法:重新连接key并重启系统。如果问题仍然存在,联系技术支持更换升级key。 |
57 |
The native configuration is not supported by the controller. Check the controller, iButton or key-vault. If you continue the configuration will be marked foreign. Press any key to continue. |
原因:控制器不支持本地配置。 处理方法:插入正确的RAID key,并重启系统。如果问题仍然存在,联系技术支持更换RAID key。 |
58 |
The battery is currently discharged or disconnected. Verify the connection and allow 30 minutes for charging. If the battery is properly connected and it has not returned to operational state after 30 minutes of charging, contact technical support for additional assistance. Press D to disable this warning (if your controller does not have a battery). |
原因:电池当前处于放电或断开状态。 处理方法:
|
59 |
The battery is currently discharged or disconnected. VDs configured in Write-Back mode will run in Write-Through mode to protect your data and will return to the Write-Back policy when the battery is operational. If VDs have not returned to Write-Back mode after 30 minutes of charging then contact technical support for additional assistance. The following VDs are affected: %s. Press any key to continue. |
原因:电池当前处于放电或断开状态。在Write Back模式下配置的虚拟磁盘将以Write Through模式运行以保护数据,当电池运行时将返回Write Back模式。 处理方法:
|
60 |
Cache data was lost, but the controller has recovered. This could be because your controller had protected cache after an unexpected power loss and your system was without power longer than the battery backup time. Press any key to continue or C to load the configuration utility. |
原因:缓存数据丢失,但控制器已恢复。这可能是因为控制器在意外断电后保护了缓存,而系统的断电时间超过了电池的备份时间。 处理方法:
|
61 |
A snapshot rollback is in progress on VDs %s, the controller cannot boot until the rollback operation completes. Press any key to enter the configuration utility. |
原因:虚拟磁盘上正在进行快照回滚,在完成之前控制器无法启动。 处理方法:等待一段时间,直到回滚完成。 |
62 |
The following VDs: %s have Rollback active and the corresponding Repository is missing. If you continue to boot the system or enter the configuration utility, these VDs will become unusable. Press any key to Continue. |
原因:这可能与快照特性有关,MegaRAID 12Gb/s SAS RAID控制器不支持快照特性。 处理方法:等待一段时间,直到回滚完成。 |
63 |
Snapshot Repository VDs %s have been removed from your system, or are no longer accessible. Check the cables and make sure all disks are present. If you continue to boot the system, the snapshot related data will be lost. Press any key to continue, or C to load the configuration utility. |
原因:控制器无法找到已配置的磁盘。 处理方法:
|
64 |
The most recent configuration command could not be committed and must be retried. Press any key to continue, or C to load the configuration utility. |
原因:无法提交最近的配置命令,必须重试。 处理方法:无 |
65 |
Firmware could not synchronize the configuration or property changes for some of the VD's/PD's. Press any key to continue, or C to load the configuration utility. |
原因:固件无法同步某些虚拟磁盘或物理磁盘的配置或属性更改。 处理方法:按任意键继续,或按“C”键加载Configuration Utility。如果问题仍然存在,联系技术支持。 |
66 |
On-board expander firmware or manufacturing image is corrupted. The flash expander firmware and manufacturing image use the recovery tools. |
原因:Expander存在软件失效问题。 处理方法: 联系技术支持。 |
67 |
The native configuration is not supported by the current firmware. Make sure that the correct controller firmware is being used. If you continue, the configuration will be marked as foreign. Press any key to continue. |
原因:当前固件不支持本地配置。 处理方法:
|
68 |
Foreign configuration import did not import any drives. Press any key to continue. |
原因:外部配置导入没有导入任何磁盘。 处理方法:
|
69 |
Valid memory detected. Firmware is upgraded from iMR to MR. Reboot the system for the MR firmware to run. |
原因:检测到有效内存。固件从iMR升级到MR。 处理方法:重启系统,使MR固件运行。 |
70 |
Advanced software options keys were detected, features activated – %s. |
原因:检测到Advanced Software Options选项,特性正在被激活。 处理方法:无 |
71 |
Advanced software options keys were missing, features deactivated – %s. |
原因:Advanced Software Options选项丢失,特性正在被停用。 处理方法:
|
72 |
Cannot communicate with iButton to retrieve premium features. This is probably because of extreme temperatures. The system has halted! |
原因:无法与RAID key通信进行高级特性检索。这可能是由极端温度引起的。 处理方法:
|
73 |
Consecutive power loss detected during I/O transactions on non-optimal write-back volumes. This might have resulted in data integrity issues. Press 'X' to proceed. |
原因:在非最优的write-back写策略的volume上,I/O活动期间发生连续多次掉电。这可能导致数据完整性问题。 处理方法:
|
74 |
USB cache device is not responding. Power down the system for 2 minutes to attempt recovery and avoid cache data loss, and then power-on. |
原因:USB缓存设备无响应。 处理方法:
|
75 |
Bad or missing RAID controller memory module detected. Press D to downgrade the RAID controller to iMR mode. Warning! Downgrading to iMR mode, might result in incompatible Logical drives. Press any other key to continue, controller shall boot to safe mode. |
原因:检测到RAID控制器内存模块损坏或丢失。 处理方法:更换RAID卡。 |