问题描述
NE40E-X3 V600R008C10SPC300 V600R008SPH033
查看esn显示两条序列号,设备上显示,一条esn为机框的,一条为主控板,这是什么情况?
<QHXN-OUT-CRT-HWNE40-2>DIS ESN
ESN of master:210305420610HB000056
ESN of slave:2102355250P0HB000010
<QHXN-OUT-CRT-HWNE40-2>DIS license ESN
ESN: 2102355250P0HB000010,210305420610HB000056
[Rack_1]
[SubRack_1]
/$[ArchivesInfo Version]
/$ArchivesInfoVersion=3.0
[Board Properties]
BoardType=CR5Z2BKPG
BarCode=2102355250P0HB000010
Item=02355250
Description=NetEngine40E-X3,CR5Z2BKPG,NE40E-X3 Integrated AC Chassis Components, (Including Dual AC Power)
Manufactured=2017-11-08
VendorName=Huawei
IssueNumber=00
CLEICode=
BOM=
[Slot_5]
/$[Board Integration Version]
/$BoardIntegrationVersion=3.0
[Main_Board_0]
/$[ArchivesInfo Version]
/$ArchivesInfoVersion=3.0
[Board Properties]
BoardType=CR52MPUD2
BarCode=210305420610HB000056
Item=03054206
Description=NetEngine40E,CR52MPUD2,Main Processing Unit D2(Including 2G Memory and 2G USB)
Manufactured=2017-11-17
VendorName=Huawei
IssueNumber=00
CLEICode=
BOM=
解决方案
设备加license之后,主控校验机框的ESN和申请的dat文件的ESN,如果不匹配就会尝试用主控板的ESN再去和dat的ESN去比对,这样就导致display esn的时候会显示框和主控板的BarCode。
核实这个设备有加载license,状态是Triial状态。
![]()
More当前的license文件,文件中的ESN与设备上框的BarCode不匹配。符合当前查看esn情况
![]()
如需显示正常,加载正确的license即可:
![]()
以上操作确认:主控校验机框的ESN和申请的dat文件的ESN不一致导致