CloudEngine 12800 and 12800E Series Switches Hardware Description
This document provides an overall description of the CE12800 series switches hardware, helping you obtain detailed information about each chassis, power module, fan module, card, cable, and pluggable modules for interface.
Switch Fabric Units
- CE-SFU04G (Switch Fabric Unit, for CE12804 Chassis)
- CE-SFU04G1 (Switch Fabric Unit, for CE12804 Chassis)
- CE-SFU08F (Switch Fabric Unit, for CE12808 Chassis)
- CE-SFU08F1 (Switch Fabric Unit, for CE12808 Chassis)
- CE-SFU08G (Switch Fabric Unit, for CE12808 Chassis)
- CE-SFU08G1 (Switch Fabric Unit, for CE12808 Chassis)
- CE-SFU12G (Switch Fabric Unit, for CE12812 Chassis)
- CE-SFU16F (Switch Fabric Unit, for CE12816 Chassis)
- CE-SFU16G (Switch Fabric Unit, for CE12816 Chassis)
- CE-SFUF-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)
- CE-SFUF1-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)
- CE-SFUG-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)
CE-SFU04G (Switch Fabric Unit, for CE12804 Chassis)
Introduction
CE-SFU04G is switching unit of the CE12804 chassis and complete line-speed switching on the data plane. Six switching units are installed in a chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU04G can be installed in: CE12804 chassis, slots 9 to 14, as shown in Slot layout in the CE12804 chassis.
The CE-SFU04G and the CE-SFU04G1 can be installed in the same chassis, but cannot be installed together with other models of SFUs.
Figure 3-90 shows the appearance of the CE-SFU04G.
Version Mapping
Product and Version Support for the CE-SFU04G
CE-SFU04G can only be used in the CE12804 chassis.
Table 3-95 lists the CE12800 series switches software versions matching the CE-SFU04G.
Functions and Features
The CE12804 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU04G is switching unit of the CE12804 chassis and complete line-speed switching on the data plane.
Table 3-96 describes the functions and features of the CE-SFU04G.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU04Gs constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU04G uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFU04G and CE-SFU04G1 look the same except that they have different card name labels. The indicator description of the CE-SFU04G1 is used as an example.
Port Description
The CE-SFU04G does not provide any ports.
Specifications
Table 3-97 lists technical specifications of the CE-SFU04G.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-98 provides CE-SFU04G ordering information.
CE-SFU04G1 (Switch Fabric Unit, for CE12804 Chassis)
Introduction
CE-SFU04G1 is switching unit of the CE12804 chassis and completes line-speed switching on the data plane. Six switching units are installed in a CE12804 chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU04G1 and the CE-SFU04G can be installed in the same chassis, but cannot be installed together with other models of SFUs.
The CE-SFU04G1 can be installed in: CE12804 chassis, slots 9 to 14, as shown in Slot layout in the CE12804 chassis.
Figure 3-91 shows the appearance of the CE-SFU04G1.
Version Mapping
Table 3-99 lists the CE12800 series switches software versions matching the CE-SFU04G1.
Functions and Features
The CE12804/CE12808/CE12812/CE12816 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU04G1 is switching unit of the CE12804 chassis and completes line-speed switching on the data plane.
Table 3-100 describes the functions and features of the CE-SFU04G1.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU04G1s constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU04G1 uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
Figure 3-92 shows indicators on the CE-SFU04G1.
Table 3-101 describes indicators on the CE-SFU04G1.
Number |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
RUN/ALM |
Running status indicator |
Green |
Steady on |
The card has been powered on but the system software is not running. |
Slow blinking |
The card is running properly. |
||||
Fast blinking |
The card is loading the system software or is resetting. |
||||
Red |
Steady on |
A fault that affects services has occurred. The fault cannot be rectified automatically and requires manual intervention. |
|||
Yellow |
Steady on |
The card is in power-off state. (For example, the card has been forcibly powered off using the power off command or is about to start.) |
|||
2 |
OFL |
Offline indicator |
To remove an SFU, hold down the OFL button for 6s. You can remove the SFU until the OFL indicator is steady red. |
||
3 |
- |
OFL button |
Port Description
The CE-SFU04G1 does not provide any ports.
Specifications
Table 3-102 lists technical specifications of the CE-SFU04G1.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-103 provides CE-SFU04G1 ordering information.
CE-SFU08F (Switch Fabric Unit, for CE12808 Chassis)
Introduction
CE-SFU08F is switching unit of the CE12808 chassis and complete line-speed switching on the data plane. Six switching units are installed in a chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU08F can be installed in: CE12808 chassis, slots 13 to 18, as shown in Slot layout in the CE12808 chassis.
The CE-SFU08F and the CE-SFU08F1 can be installed in the same chassis, but cannot be installed together with other models of SFUs.
Figure 3-93 shows the appearance of the CE-SFU08F.
Version Mapping
Product and Version Support for the CE-SFU08F
The CE-SFU08F can only be used in the CE12808 chassis.
Table 3-104 lists the CE12800 series switches software versions matching the CE-SFU08F.
Functions and Features
The CE12808 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU08F is switching unit of the CE12808 chassis and complete line-speed switching on the data plane.
Table 3-105 describes the functions and features of the CE-SFU08F.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU08Fs constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU08F uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFU08F and CE-SFU04G1 look the same except that they have different card name labels. The indicator description of the CE-SFU04G1 is used as an example.
Port Description
The CE-SFU08F does not provide any ports.
Specifications
Table 3-106 lists technical specifications of the CE-SFU08F.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-107 provides CE-SFU08F ordering information.
CE-SFU08F1 (Switch Fabric Unit, for CE12808 Chassis)
Introduction
CE-SFU08F1 is switching unit of the CE12808 chassis and completes line-speed switching on the data plane. Six switching units are installed in a CE12808 chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU08F1 and the CE-SFU08F can be installed in the same chassis, but cannot be installed together with other models of SFUs.
The CE-SFU08F1 can be installed in: CE12808 chassis, slots 13 to 18, as shown in Slot layout in the CE12808 chassis.
Figure 3-94 shows the appearance of the CE-SFU08F1.
Version Mapping
Table 3-108 lists the CE12800 series switches software versions matching the CE-SFU08F1.
Functions and Features
The CE12804/CE12808/CE12812/CE12816 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU08F1 is switching unit of the CE12808 chassis and completes line-speed switching on the data plane.
Table 3-109 describes the functions and features of the CE-SFU08F1.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU08F1s constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU08F1 uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
Figure 3-95 shows indicators on the CE-SFU08F1.
Table 3-110 describes indicators on the CE-SFU08F1.
Number |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
RUN/ALM |
Running status indicator |
Green |
Steady on |
The card has been powered on but the system software is not running. |
Slow blinking |
The card is running properly. |
||||
Fast blinking |
The card is loading the system software or is resetting. |
||||
Red |
Steady on |
A fault that affects services has occurred. The fault cannot be rectified automatically and requires manual intervention. |
|||
Yellow |
Steady on |
The card is in power-off state. (For example, the card has been forcibly powered off using the power off command or is about to start.) |
|||
2 |
OFL |
Offline indicator |
To remove an SFU, hold down the OFL button for 6s. You can remove the SFU until the OFL indicator is steady red. |
||
3 |
- |
OFL button |
Port Description
The CE-SFU08F1 does not provide any ports.
Specifications
Table 3-111 lists technical specifications of the CE-SFU08F1.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-112 provides CE-SFU08F1 ordering information.
CE-SFU08G (Switch Fabric Unit, for CE12808 Chassis)
Introduction
CE-SFU08G is switching unit of the CE12808 chassis and complete line-speed switching on the data plane. Six switching units are installed in a chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU08G can be installed in: CE12808 chassis, slots 13 to 18, as shown in Slot layout in the CE12808 chassis.
The CE-SFU08G and the CE-SFU08G1 can be installed in the same chassis, but cannot be installed together with other models of SFUs.
Figure 3-96 shows the appearance of the CE-SFU08G.
Version Mapping
Product and Version Support for the CE-SFU08G
The CE-SFU08G can only be used in the CE12808 chassis.
Table 3-113 lists the CE12800 series switches software versions matching the CE-SFU08G.
Functions and Features
The CE12808 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU08G is switching unit of the CE12808 chassis and complete line-speed switching on the data plane.
Table 3-114 describes the functions and features of the CE-SFU08G.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU08Gs constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU08G uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFU08G and CE-SFU04G1 look the same except that they have different card name labels. The indicator description of the CE-SFU04G1 is used as an example.
Port Description
The CE-SFU08G does not provide any ports.
Specifications
Table 3-115 lists technical specifications of the CE-SFU08G.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-116 provides CE-SFU08G ordering information.
CE-SFU08G1 (Switch Fabric Unit, for CE12808 Chassis)
Introduction
CE-SFU08G1 is switching unit of the CE12808 chassis and completes line-speed switching on the data plane. Six switching units are installed in a CE12808 chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU08G1 and the CE-SFU08G can be installed in the same chassis, but cannot be installed together with other models of SFUs.
The CE-SFU08G1 can be installed in: CE12808 chassis, slots 13 to 18, as shown in Slot layout in the CE12808 chassis.
Figure 3-97 shows the appearance of the CE-SFU08G1.
Version Mapping
Table 3-117 lists the CE12800 series switches software versions matching the CE-SFU08G1.
Functions and Features
The CE12804/CE12808/CE12812/CE12816 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU08G1 is switching unit of the CE12808 chassis and completes line-speed switching on the data plane.
Table 3-118 describes the functions and features of the CE-SFU08G1.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU08G1s constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU08G1 uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFU08G1 and CE-SFU04G1 look the same except that they have different card name labels. The indicator description of the CE-SFU04G1 is used as an example.
Port Description
The CE-SFU08G1 does not provide any ports.
Specifications
Table 3-119 lists technical specifications of the CE-SFU08G1.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-120 provides CE-SFU ordering information.
CE-SFU12G (Switch Fabric Unit, for CE12812 Chassis)
Introduction
CE-SFU12G is switching units of the CE12812 chassis and complete line-speed switching on the data plane. Six switching units are installed in a chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU12G can be installed in: CE12812 chassis, slots 17 to 22, as shown in Slot layout in the CE12812 chassis.
SFUs in the same chassis must be the same model.
Figure 3-98 shows the appearance of the CE-SFU12G.
Version Mapping
Product and Version Support for the CE-SFU12G
The CE-SFU12G can only be used in the CE12812 chassis.
Table 3-121 lists the CE12800 series switches software versions matching the CE-SFU12G.
Functions and Features
The CE12812 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU12G is switching unit of the CE12812 chassis and complete line-speed switching on the data plane.
Table 3-122 describes the functions and features of the CE-SFU12G.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU12Gs constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU12G uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFU12G and CE-SFU04G1 look the same except that they have different card name labels. The indicator description of the CE-SFU04G1 is used as an example.
Port Description
The CE-SFU12G does not provide any ports.
Specifications
Table 3-123 lists technical specifications of the CE-SFU12G.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-124 provides CE-SFU ordering information.
CE-SFU16F (Switch Fabric Unit, for CE12816 Chassis)
Introduction
CE-SFU16F is switching units of the CE12816 chassis and complete line-speed switching on the data plane. Six switching units are installed in a chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU16F can be installed in: CE12816 chassis, Slot 21 to 26, as shown in Slot layout in the CE12816 chassis
The CE-SFU16F cannot be installed together with other models of SFUs.
Figure 3-99 shows the appearance of the CE-SFU16F.
Version Mapping
Product and Version Support for the CE-SFU16F
The CE-SFU16F can only be used in the CE12816 chassis.
Table 3-125 lists the CE12800 series switches software versions matching the CE-SFU16F.
Functions and Features
The CE12816 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU16F is switching units of the CE12816 chassis and complete line-speed switching on the data plane.
Table 3-126 describes the functions and features of the CE-SFU16F.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU16Fs constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU16F uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFU16F and CE-SFU04G1 look the same except that they have different card name labels. The indicator description of the CE-SFU04G1 is used as an example.
Port Description
The CE-SFU16F does not provide any ports.
Specifications
Table 3-127 lists technical specifications of the CE-SFU16F.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-128 provides CE-SFU16F ordering information.
CE-SFU16G (Switch Fabric Unit, for CE12816 Chassis)
Introduction
CE-SFU16G is switching units of the CE12816 chassis and complete line-speed switching on the data plane. Six switching units are installed in a chassis and work in load balancing and redundancy mode to improve system reliability.
The CE-SFU16G can be installed in: CE12816 chassis, Slot 21 to 26, as shown in Slot layout in the CE12816 chassis
The CE-SFU16G cannot be installed together with other models of SFUs.
Figure 3-100 shows the appearance of the CE-SFU16G.
Version Mapping
Product and Version Support for the CE-SFU16G
The CE-SFU16G can only be used in the CE12816 chassis.
Table 3-129 lists the CE12800 series switches software versions matching the CE-SFU16G.
Functions and Features
The CE12816 series switches use a system architecture with separate control plane, data plane, and monitoring plane.
CE-SFU16G is switching units of the CE12816 chassis and complete line-speed switching on the data plane.
Table 3-130 describes the functions and features of the CE-SFU16G.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Six CE-SFU16Gs constitute the switching core of the data plane and provide high-speed Serdes channels for LPUs. |
Reliability |
The CE-SFU16G uses a single-stage multi-plane switch fabric to expand the switching capacity. The system has six switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFU16G and CE-SFU04G1 look the same except that they have different card name labels. The indicator description of the CE-SFU04G1 is used as an example.
Port Description
The CE-SFU16G does not provide any ports.
Specifications
Table 3-131 lists technical specifications of the CE-SFU16G.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the product manager of the Huawei local office.
Table 3-132 provides CE-SFU16G ordering information.
Part Number |
Card Name |
Card Description |
---|---|---|
03023CLV |
CE-SFU16G |
CE12816 Switch Fabric Unit G |
03025RXL |
CE-SFU16G |
CE12816 Switch Fabric Unit G |
The CE-SFU16G card with the part number 03025RXL is supported in V200R019C10SPC900 and later versions.
CE-SFUF-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)
Introduction
The CE-SFUF-S is the switch fabric unit of the CE12804S/CE12808S chassis and completes line-speed switching on the data plane. Each CE12804S chassis is configured with two CE-SFUF-S cards, and each CE12808S chassis is configured with four CE-SFUF-S cards. The CE-SFUF-S in a chassis work in load balancing and redundancy mode to improve system reliability.
The CE-SFUF-S can be installed in:
- Slot 7 and slot 8 of the CE12804S chassis, as shown in Figure 3-41
- Slots 11 to 14 of the CE12808S chassis, as shown in Figure 3-49
- The CE-SFUF-S and the CE-SFUF1-S can be installed in the same chassis, but cannot be installed together with other models of SFUs.
For the CE12808S running V200R002C50 or an earlier version, if CE-SFUF-S SFUs or CE-SFUF1-S SFUs are installed only in slots 13 and 14 and no SFU is installed in slots 11 and 12, a newly installed CE-L36CQ-FD card cannot be registered. In V200R003C00 and later versions, a newly installed CE-L36CQ-FD card can be registered in this scenario, but there are the following limitations:
- The interfaces using chips 0 and 5 on the CE-L36CQ-FD card are in Error-Down state. The interfaces are 100GE interfaces 0 to 5 and 100GE interfaces 30 to 35.
- The protocol packets proactively sent by chips 1 to 4 on the CE-L36CQ-FD card need to be forwarded by chip 0. Because chip 0 cannot communicate with SFUs, the interfaces using chips 1 to 4 on the CE-L36CQ-FD card fail to send protocol packets. As a result, services are interrupted.
In this case, change the SFU slots and install an SFU in slot 11 or 12. Alternatively, install more SFUs, or replace the SFUs with CE-SFUG-S.
Figure 3-101 shows the appearance of the CE-SFUF-S.
Version Mapping
The CE-SFUF-S can only be used in the CE12804S or CE12808S chassis.
Table 3-133 lists the CE12800 series switches software versions matching the CE-SFUF-S.
Functions and Features
The CE12804S/CE12808S series switches use a system architecture with separate control plane, data plane, and monitoring plane.
The CE-SFUF-S is the switch fabric unit of the CE12804S/CE12808S chassis and completes line-speed switching on the data plane.
Table 3-134 describes the functions and features of the CE-SFUF-S.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Two/Four CE-SFUF-S cards in a chassis constitute the switching core of the data plane and provide high-speed SerDes channels for LPUs. |
Reliability |
The CE-SFUF-S cards in a chassis use a single-stage multi-plane switch fabric to expand the switching capacity. The system has two/four switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFUF-S and CE-SFUF1-S look the same except that they have different card name labels. Figure 3-103 shows the appearance of the CE-SFUF1-S as an example.
Port Description
The CE-SFUF-S does not provide any ports.
Specifications
Table 3-135 lists technical specifications of the CE-SFUF-S.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the Huawei local office.
Table 3-136 provides CE-SFUF-S ordering information.
CE-SFUF1-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)
Introduction
The CE-SFUF1-S is the switch fabric unit of the CE12804S/CE12808S chassis and completes line-speed switching on the data plane. Each CE12804S chassis is configured with two SFUs, and each CE12808S chassis is configured with four SFUs. The SFUs in a chassis work in load balancing and redundancy mode to improve system reliability.
- The CE-SFUF1-S and the CE-SFUF-S can be installed in the same chassis, but cannot be installed together with other models of SFUs.
Figure 3-102 shows the appearance of the CE-SFUF1-S.
Version Mapping
The CE-SFUF1-S can only be used in the CE12804S or CE12808S chassis.
Table 3-137 lists the CE12800 series switches software versions matching the CE-SFUF1-S.
Functions and Features
The CE12804S/CE12808S series switches use a system architecture with separate control plane, data plane, and monitoring plane.
The CE-SFUF1-S is the switch fabric unit of the CE12804S/CE12808S chassis and completes line-speed switching on the data plane.
Table 3-138 describes the functions and features of the CE-SFUF1-S.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Two/Four CE-SFUF1-S cards in a chassis constitute the switching core of the data plane and provide high-speed SerDes channels for LPUs. |
Reliability |
The CE-SFUF1-S cards in a chassis use a single-stage multi-plane switch fabric to expand the switching capacity. The system has two/four switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
Figure 3-103 shows indicators on the CE-SFUF1-S.
Table 3-139 describes indicators on the CE-SFUF1-S.
Number |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
RUN/ALM |
Running status indicator |
Green |
Steady on |
The card has been powered on but the system software is not running. |
Slow blinking |
The card is running properly. |
||||
Fast blinking |
The card is loading the system software or is resetting. |
||||
Red |
Steady on |
A fault that affects services has occurred. The fault cannot be rectified automatically and requires manual intervention. |
|||
Yellow |
Steady on |
The card is in power-off state. (For example, the card has been forcibly powered off using the power off command or is about to start.) |
|||
2 |
OFL |
Offline indicator |
To remove an SFU, hold down the OFL button for 6s. You can remove the SFU until the OFL indicator is steady red. |
||
3 |
- |
OFL button |
Port Description
The CE-SFUF1-S does not provide any ports.
Specifications
Table 3-140 lists technical specifications of the CE-SFUF1-S.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the Huawei local office.
Table 3-141 provides CE-SFUF1-S ordering information.
CE-SFUG-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)
Introduction
The CE-SFUG-S is the switch fabric unit of the CE12804S/CE12808S chassis and completes line-speed switching on the data plane. Each CE12804S chassis is configured with two CE-SFUG-S cards, and each CE12808S chassis is configured with four CE-SFUG-S cards. The CE-SFUG-S in a chassis work in load balancing and redundancy mode to improve system reliability.
The CE-SFUG-S can be installed in:
- Slot 7 and slot 8 of the CE12804S chassis, as shown in Slot layout in the CE12804S chassis
- Slots 11 to 14 of the CE12808S chassis, as shown in Slot layout in the CE12808S chassis
- CE-SFUG-S cannot be installed together with other models of SFUs in the same chassis.
Figure 3-104 shows the appearance of the CE-SFUG-S.
Version Mapping
The CE-SFUG-S can only be used in the CE12804S or CE12808S chassis.
Table 3-142 lists the CE12800 series switches software versions matching the CE-SFUG-S.
Functions and Features
The CE12804S/CE12808S series switches use a system architecture with separate control plane, data plane, and monitoring plane.
The CE-SFUG-S is the switch fabric unit of the CE12804S/CE12808S chassis and completes line-speed switching on the data plane.
Table 3-143 describes the functions and features of the CE-SFUG-S.
Function and Feature |
Description |
---|---|
Line-speed data switching |
Two/Four CE-SFUG-S cards in a chassis constitute the switching core of the data plane and provide high-speed SerDes channels for LPUs. |
Reliability |
The CE-SFUG-S cards in a chassis use a single-stage multi-plane switch fabric to expand the switching capacity. The system has two/four switching planes, which work in load balancing and redundancy mode to ensure nonstop service data switching. |
Indicators and Ports
Indicator Description
The CE-SFUG-S and CE-SFUF1-S look the same except that they have different card name labels. Figure 3-103 shows the appearance of the CE-SFUF1-S as an example.
Port Description
The CE-SFUG-S does not provide any ports.
Specifications
Table 3-144 lists technical specifications of the CE-SFUG-S.
Item |
Description |
---|---|
Reliability |
Load balancing and redundancy design |
Physical specifications |
|
Environment parameters |
|
Certification |
|
Ordering Information
To place an order, contact the Huawei local office.
Table 3-145 provides CE-SFUG-S ordering information.
- CE-SFU04G (Switch Fabric Unit, for CE12804 Chassis)
- CE-SFU04G1 (Switch Fabric Unit, for CE12804 Chassis)
- CE-SFU08F (Switch Fabric Unit, for CE12808 Chassis)
- CE-SFU08F1 (Switch Fabric Unit, for CE12808 Chassis)
- CE-SFU08G (Switch Fabric Unit, for CE12808 Chassis)
- CE-SFU08G1 (Switch Fabric Unit, for CE12808 Chassis)
- CE-SFU12G (Switch Fabric Unit, for CE12812 Chassis)
- CE-SFU16F (Switch Fabric Unit, for CE12816 Chassis)
- CE-SFU16G (Switch Fabric Unit, for CE12816 Chassis)
- CE-SFUF-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)
- CE-SFUF1-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)
- CE-SFUG-S (Switch Fabric Unit, for CE12804S/CE12808S Chassis)