CloudEngine 8800, 7800, 6800, and 5800 Series Switches Hardware Description (Versions earlier than V200R020C00)

This document provides an overall description of the CE5800&6800&7800&8800 series switches hardware that versions earlier than V200R020C00, helping you obtain detailed information about each chassis, power module, fan module, card, cable, and pluggable modules for ports.

CE8868-4C-EI

CE8868-4C-EI

Version Mapping

Table 2-344 lists the mappings between the CE8868-4C-EI and software versions.

Table 2-344 Version mapping

Device Series

Sub-series

Device Model

Short Name

Supported Version

CE8800

CE8868

CE8868-4C-EI

CE8868EI

V200R005C10 to V200R019C10

NOTE:

This model is not supported in V200R005C20.

Appearance and Structure

The figures in this document are for reference only.

Figure 2-165 CE8868-4C-EI

1

Ground screw

2

Two ETH management ports (RJ45)

3

ESN and MAC address label

4

Console port

5

USB port

6

Mini USB port

7

Fan slot 1

Applicable fan modules:
  • FAN-180A Series Fan Modules

8

Fan slot 2

Applicable fan modules:
  • FAN-180A Series Fan Modules

9

Power supply slot 1

Applicable power modules:
  • 1200 W AC&240 V DC Power Module (PAC-1K2WA)
  • 1200 W High-voltage DC Power Module (PHD-1K2WA)
  • 1200 W DC Power Module (PDC-1K2WA)

10

Power supply slot 2

Applicable power modules:
  • 1200 W AC&240 V DC Power Module (PAC-1K2WA)
  • 1200 W High-voltage DC Power Module (PHD-1K2WA)
  • 1200 W DC Power Module (PDC-1K2WA)

11

Extended card slot 1

12

Extended card slot 2

13

Extended card slot 3

14

Extended card slot 4

15

Mounting holes for mounting brackets

-

-

Slot

  • Power supply slot

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).
    • When both power modules are working properly, they equally provide power for a chassis.
    • When one power module fails, the other one provides all power required for a chassis.
    All power modules are hot swappable.
  • Fan slot

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.

    All fan modules are hot swappable.

Airflow

The cooling systems of the CloudEngine 8800, 7800, 6800, and 5800 series switches have front-to-back or back-to-front airflow depending on the airflow direction of the power modules and fan modules used. The airflow direction of the power modules and fan modules required on the CloudEngine 8800, 7800, 6800, and 5800 series switches depends on how the switches are installed in cabinets. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If CloudEngine 8800, 7800, 6800, and 5800 series switches are installed with the power supply side facing the front, you are advised to use fan modules and power modules with front-to-back airflow in the switches.
  • Front-to-back airflow: The power modules and fan modules using front-to-back airflow are marked or . Air flows into the chassis from the power supply side and flows out from the port side, as shown in Figure 2-166 (CE5800 as an example).
  • Back-to-front airflow: The power modules and fan modules using back-to-front airflow are marked or . Air flows into the chassis from the port side and flows out from the power supply side, as shown in Figure 2-110 (CE5800 as an example).
  • When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.

Figure 2-166 Front-to-back airflow (air flows out from the port side)
Figure 2-167 Back-to-front airflow (air flows in from the port side)

Indicators

Indicators on the CE8868-4C-EI are the same as those on the CE8861-4C-EI. The CE8861-4C-EI is used as an example here to describe the indicators.

Ports

Console Port

The console port is connected to a console for onsite configuration. The port must use a console cable. Table 2-345 describes the attributes of the console port.
Table 2-345 Attributes of the console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s to 115200 bit/s

Default value: 9600 bit/s

  • The console port and Mini USB port share one internal serial port. You can use the console port or Mini USB port as the serial port according to your needs. When the Mini USB is activated, the console port cannot be used.
  • When both the console port and Mini-USB port have a cable connected, the Mini-USB port is used.

Mini USB Port

The Mini USB port can connect to a configuration terminal for onsite configuration of the system, but the configuration terminal must have a USB serial port driver installed. The Mini USB port is used as the serial port once a link is established on the port.

ETH Management Port (RJ45)

The ETH management port (RJ45) of a switch is connected to the network port of a configuration terminal or network management workstation to set up the onsite or remote configuration environment. The ETH management port (RJ45) uses a Category 5 or higher category cable. Table 2-346 describes the attributes of the ETH management port (RJ45).
Table 2-346 Attributes of the ETH management port (RJ45)

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3ab

Working mode

Supported rate: 10/100/1000 Mbit/s auto-sensing

Full-duplex

Maximum transmission distance

100 m

The CE8868EI switches have two ETH management ports (RJ45). Pay attention to the following when using the two management ports:
  • The two ports cannot be used together, and you must choose one of them to use.
  • Before start of a CE8868EI switch, you can select interface 1 or interface 2 in the BIOS menu. Interface 1 is the default choice. For details, see "Modify parameters" in the Basic Configuration Guide - BIOS Menu.
  • After registration of the switch succeeds:
    • If both the management ports have a cable connected and are in Up state, port 1 acts as the primary management port and port 2 becomes the backup automatically. The management interface number displayed on the command line interface is MEth0/0/0, regardless of which port is used.
    • If cables are connected to the two ETH management ports after successful registration of the switch, the port that is connected first is used as the primary management port.
    • If port 1 fails, the system switches management traffic to port 2 automatically. When port 1 recovers, management traffic cannot be switched back to port 1, unless port 2 fails or the switch restarts. You can observe indicators on the ETH management ports to determine which port is used currently. (The Link indicator of the ETH management port used is steady green. If data is being transmitted on this port, its ACT indicator is blinking yellow. The indicators of the backup port are off.)

USB Port

A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.

Specifications

Table 2-347 lists technical specifications of the CE8868-4C-EI switch.

Table 2-347 Technical specifications

Item

Description

Physical specifications

  • Dimensions (W x D x H): 442.0 mm x 600.0 mm x 88.1 mm (17.4 in. x 23.6 in. x 3.47 in.)
  • Weight (with two power modules and two fan modules, calculated based on the heaviest model if multiple models are supported): 21.3 kg

Environment parameters

Temperature

  • Operating temperature: 0°C to 40°C (32°F to 104°F) at altitude of 0-1800 m (0-5906 ft.)
    NOTE:

    When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

  • Storage temperature: -40°C to +70°C (-40°F to +158°F)

Relative humidity

5% RH to 95% RH, noncondensing

Altitude

< 5000 m (16404 ft.)

Noise (sound pressure, 27°C)

  • Back-to-front airflow: < 58 dBA
  • Front-to-back airflow: < 56 dBA

Power specifications

Power source type

AC/DC/high-voltage DC

AC power input

  • Rated input voltage range: 100 V AC to 130 V AC/200 V AC to 240 V AC, 50/60 Hz
  • Maximum input voltage range: 90 V AC to 290 V AC, 47 Hz to 63 Hz

DC power input

  • Rated voltage range: -48 V DC to -60 V DC
  • Maximum voltage range: -38.4 V DC to -72 V DC

High-voltage DC power input

  • Rated voltage of 240 V high-voltage DC power input: 240 V DC
  • Maximum voltage range of 240 V high-voltage DC power input: 188 V DC to 290 V DC
  • Rated voltage range of 380 V high-voltage DC power input: 240 V DC to 380 V DC
  • Maximum voltage range of 380 V high-voltage DC power input: 188 V DC to 400 V DC

Rated input current

  • 1200 W AC&240 V DC power module (PAC-1K2WA series): 10 A (100 V AC to 130 V AC)/8 A (200 V AC to 240 V AC)/8 A (240 V DC)
  • 1200 W high-voltage DC power module (PHD-1K2WA series): 8 A (240 V DC to 380 V DC)
  • 1200 W DC power (PDC-1K2WA series): 38 A (-48 V DC to -60 V DC)

Chassis power consumption

Maximum power consumption

  • Fully configured with four CE88-D8CQ cards: 658 W
  • Fully configured with four CE88-D16Q cards: 620 W
  • Fully configured with four CE88-D24T2CQ cards: 747 W
  • Fully configured with four CE88-D24S2CQ cards: 674 W

Typical power consumption

  • Fully configured with four CE88-D8CQ cards: 398 W (100% throughput, QSFP28 cables on 32 ports, double power modules)
  • Fully configured with four CE88-D16Q cards: 383 W (100% throughput, QSFP+ cables on 64 ports, double power modules)
  • Fully configured with four CE88-D24T2CQ cards: 532 W (100% throughput, 3 m Ethernet cables on 96 ports and QSFP28 cables on 8 ports, double power modules)
  • Fully configured with four CE88-D24S2CQ cards: 437 W (100% throughput, SFP28 cables on 96 ports and QSFP28 cables on 8 ports, double power modules)

Chassis heat dissipation

Maximum heat dissipation

  • Fully configured with four CE88-D8CQ cards: 2245 BTU/hr
  • Fully configured with four CE88-D16Q cards: 2116 BTU/hr
  • Fully configured with four CE88-D24T2CQ cards: 2549 BTU/hr
  • Fully configured with four CE88-D24S2CQ cards: 2300 BTU/hr

Typical heat dissipation

  • Fully configured with four CE88-D8CQ cards: 1358 BTU/hr (100% throughput, QSFP28 cables on 32 ports, double power modules)
  • Fully configured with four CE88-D16Q cards: 1307 BTU/hr (100% throughput, QSFP+ cables on 64 ports, double power modules)
  • Fully configured with four CE88-D24T2CQ cards: 1815 BTU/hr (100% throughput, 3 m Ethernet cables on 96 ports and QSFP28 cables on 8 ports, double power modules)
  • Fully configured with four CE88-D24S2CQ cards: 1491 BTU/hr (100% throughput, SFP28 cables on 96 ports and QSFP28 cables on 8 ports, double power modules)

Surge protection

Power module:
  • AC: 4 kV in common mode and 2.5 kV in differential mode
  • DC: 4 kV in common mode and 2 kV in differential mode

Heat dissipation

Heat dissipation mode

Air cooling

Airflow

Front-to-back or back-to-front, which is determined by features of fan modules and power modules

Reliability and availability

Power module backup

1+1 backup

Fan module backup

Two fan modules, working in 1+1 backup mode when the temperature is below 35°C

Hot swap

Supported by all power modules and fan modules

Mean time between failures (MTBF)

36.02 years

Mean time to repair (MTTR)

1.87 hours

Availability

0.9999940608

Technical specifications

Processor

1.5 GHz, eight-core

DRAM Memory

4 GB

NOR Flash

32 MB

NAND Flash

2 GB

Stack

Service port supporting the stack function

See the description of ports on each card.

Certification

  • Safety standards compliance
  • EMC standards compliance
  • Environmental standards compliance

Ordering Information

Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.

Table 2-348 provides the ordering information.

Table 2-348 Ordering information

Part Number

Part Model

Part Description

02352CHJ

CE8868-4C-EI

CE8868-4C-EI Mainframe (With 4 Subcard Slots, Without FAN Box and Power Module)

02352CHN

CE8868-4C-EI-F

CE8868-4C-EI Mainframe (With 4 Subcard Slots, 2*AC Power Module, 2*FAN Box, Port-side Exhaust)

02352CHM

CE8868-4C-EI-B

CE8868-4C-EI Mainframe (With 4 Subcard Slots, 2*AC Power Module, 2*FAN Box, Port-side Intake)

Translation
Favorite
Download
Update Date:2021-06-01
Document ID:EDOC1000019246
Views:1409518
Downloads:15535
Average rating:3.86Points

Digital Signature File

digtal sigature tool