CloudEngine 8800, 7800, 6800, and 5800 Series Switches Hardware Description (Versions earlier than V200R020C00)
This document provides an overall description of the CE5800&6800&7800&8800 series switches hardware that versions earlier than V200R020C00, helping you obtain detailed information about each chassis, power module, fan module, card, cable, and pluggable modules for ports.
CE8868-4C-EI
Version Mapping
Table 2-344 lists the mappings between the CE8868-4C-EI and software versions.
Appearance and Structure
The figures in this document are for reference only.
1 |
Ground screw |
2 |
Two ETH management ports (RJ45) |
3 |
ESN and MAC address label |
4 |
Console port |
5 |
USB port |
6 |
Mini USB port |
7 |
Fan slot 1 Applicable fan modules:
|
8 |
Fan slot 2 Applicable fan modules:
|
9 |
Power supply slot 1 Applicable power modules:
|
10 |
Power supply slot 2 Applicable power modules:
|
11 |
Extended card slot 1 Applicable cards:
|
12 |
Extended card slot 2 Applicable cards:
|
13 |
Extended card slot 3 Applicable cards:
|
14 |
Extended card slot 4 Applicable cards:
|
15 |
Mounting holes for mounting brackets |
- |
- |
Slot
Power supply slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).- When both power modules are working properly, they equally provide power for a chassis.
- When one power module fails, the other one provides all power required for a chassis.
Fan slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.
All fan modules are hot swappable.
Airflow
- Front-to-back airflow: The power modules and fan modules using front-to-back airflow are marked or . Air flows into the chassis from the power supply side and flows out from the port side, as shown in Figure 2-166 (CE5800 as an example).
- Back-to-front airflow: The power modules and fan modules using back-to-front airflow are marked or . Air flows into the chassis from the port side and flows out from the power supply side, as shown in Figure 2-110 (CE5800 as an example).
When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.
Indicators
Indicators on the CE8868-4C-EI are the same as those on the CE8861-4C-EI. The CE8861-4C-EI is used as an example here to describe the indicators.
Ports
Console Port
- The console port and Mini USB port share one internal serial port. You can use the console port or Mini USB port as the serial port according to your needs. When the Mini USB is activated, the console port cannot be used.
- When both the console port and Mini-USB port have a cable connected, the Mini-USB port is used.
Mini USB Port
The Mini USB port can connect to a configuration terminal for onsite configuration of the system, but the configuration terminal must have a USB serial port driver installed. The Mini USB port is used as the serial port once a link is established on the port.
ETH Management Port (RJ45)
- The two ports cannot be used together, and you must choose one of them to use.
- Before start of a CE8868EI switch, you can select interface 1 or interface 2 in the BIOS menu. Interface 1 is the default choice. For details, see "Modify parameters" in the Basic Configuration Guide - BIOS Menu.
- After registration of the switch succeeds:
- If both the management ports have a cable connected and are in Up state, port 1 acts as the primary management port and port 2 becomes the backup automatically. The management interface number displayed on the command line interface is MEth0/0/0, regardless of which port is used.
- If cables are connected to the two ETH management ports after successful registration of the switch, the port that is connected first is used as the primary management port.
- If port 1 fails, the system switches management traffic to port 2 automatically. When port 1 recovers, management traffic cannot be switched back to port 1, unless port 2 fails or the switch restarts. You can observe indicators on the ETH management ports to determine which port is used currently. (The Link indicator of the ETH management port used is steady green. If data is being transmitted on this port, its ACT indicator is blinking yellow. The indicators of the backup port are off.)
USB Port
A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.
Specifications
Table 2-347 lists technical specifications of the CE8868-4C-EI switch.
Item |
Description |
|
---|---|---|
Physical specifications |
|
|
Environment parameters |
Temperature |
|
Relative humidity |
5% RH to 95% RH, noncondensing |
|
Altitude |
< 5000 m (16404 ft.) |
|
Noise (sound pressure, 27°C) |
|
|
Power specifications |
Power source type |
AC/DC/high-voltage DC |
AC power input |
|
|
DC power input |
|
|
High-voltage DC power input |
|
|
Rated input current |
|
|
Chassis power consumption |
Maximum power consumption |
|
Typical power consumption |
|
|
Chassis heat dissipation |
Maximum heat dissipation |
|
Typical heat dissipation |
|
|
Surge protection |
Power module:
|
|
Heat dissipation |
Heat dissipation mode |
Air cooling |
Airflow |
Front-to-back or back-to-front, which is determined by features of fan modules and power modules |
|
Reliability and availability |
Power module backup |
1+1 backup |
Fan module backup |
Two fan modules, working in 1+1 backup mode when the temperature is below 35°C |
|
Hot swap |
Supported by all power modules and fan modules |
|
Mean time between failures (MTBF) |
36.02 years |
|
Mean time to repair (MTTR) |
1.87 hours |
|
Availability |
0.9999940608 |
|
Technical specifications |
Processor |
1.5 GHz, eight-core |
DRAM Memory |
4 GB |
|
NOR Flash |
32 MB |
|
NAND Flash |
2 GB |
|
Stack |
Service port supporting the stack function |
See the description of ports on each card. |
Certification |
|
Ordering Information
Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.
Table 2-348 provides the ordering information.
Part Number |
Part Model |
Part Description |
---|---|---|
02352CHJ |
CE8868-4C-EI |
CE8868-4C-EI Mainframe (With 4 Subcard Slots, Without FAN Box and Power Module) |
02352CHN |
CE8868-4C-EI-F |
CE8868-4C-EI Mainframe (With 4 Subcard Slots, 2*AC Power Module, 2*FAN Box, Port-side Exhaust) |
02352CHM |
CE8868-4C-EI-B |
CE8868-4C-EI Mainframe (With 4 Subcard Slots, 2*AC Power Module, 2*FAN Box, Port-side Intake) |