PID Module User Manual

This document describes the PID installation, electrical connections, maintenance, and troubleshooting.

Changing the RS485 Address over the WebUI

Changing the RS485 Address over the WebUI

Procedure

  1. Enter https://XX.XX.XX.XX in the address box of the browser, and press Enter. The login page is displayed, as shown in Figure A-1. Specify Language, User Name, and Password, and click Log In to display the main menu.

    Figure A-1 Login page of the WebUI

    NOTE:
    • Because of the permission restriction, log in as Advanced User or Special User.
    • XX.XX.XX.XX is the IP address for the SmartLogger. The default IP address is 192.168.0.10.
    • If the SmartLogger software version is SUN2000 V100R001C95SPC010 or earlier, the initial password is 000001. If the SmartLogger software version is SUN2000 V100R001C95SPC020 or later or SmartLogger V100R001C00SPC010 or later, the initial password is Changeme.
    • Use the initial password upon first power-on and change it immediately after login. To ensure account security, change the password periodically and keep the new password in mind. Not changing the initial password may cause password disclosure. A password left unchanged for a long period of time may be stolen or cracked. If a password is lost, devices cannot be accessed. In these cases, the user is liable for any loss caused to the PV plant. For details about how to change the password, see SmartLogger User Manual or SUN2000 APP User Manual.

  2. On the Maintenance tab page, choose Device Mgmt. > Connect Device. Then click Connect Device in the lower part of the Auto Assign Address page, as shown in Figure A-2.

    Figure A-2 Automatic address assigning

    NOTE:
    Set start addr. to a value in the range of 1–247 based on site requirements.

  3. Click Auto Assign Address and then OK. In the displayed dialog box, click OK, as shown in Figure A-3.

    Figure A-3 Address adjustment

  4. In the Address Adjustment dialog box, change the device address corresponding to the serial number of the PID module, and then click Address Adjustment, as shown in Figure A-4.

    Figure A-4 Changing the address

  5. Click OK to start the automatic searching, as shown in Figure A-5.

    Figure A-5 Searching for the device again

  6. After the searching is complete, click OK.